Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All
     

    Related Documentation

     

    Bring an SFM Online

    To bring an SFM online, use the following command:

    user@host> request chassis sfm slot slot-number online
    user@host> request chassis sfm slot 0 online
    Online initiated, use "show chassis sfm" to verify
    

    For M40e routers:

    user@host> show chassis sfm
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Present            0      0          0         0         0          0
      1  Online - Standby  41      4          0        64        16         46
    

    For M160 routers:

    user@host> show chassis sfm
    Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online            41      3          0        64        17         46
      1  Online            44      3          0        64        17         46
      2  Online            44      3          0        64        17         46
      3  Present            0      0          0         0         0          0
    Packet scheduling mode: Disabled
    

    The sample output confirms that the SFM online command has been initiated and specifies to use the show chassis sfm command to verify that the SFM is online. The command output shows that the SFM is present and that the values for the SFM status are 0 for approximately 5 seconds until the SFM is active.

     

    Related Documentation

     

    Published: 2012-08-20