Monitoring the SRX100 Services Gateway Using Chassis Alarm Conditions

 

When the services gateway detects an alarm condition, the alarm LED on the front panel turns red or amber as appropriate.

To view a more detailed description of the alarm cause, issue the show chassis alarms CLI command.

For more information on the show chassis alarms command, see the following topics:

Table 1 describes alarms that can occur for an SRX100 Services Gateway chassis component.

Table 1: SRX100 Services Gateway Chassis Alarm Conditions and Corrective Actions

Component

Alarm Conditions

Action

Alarm Severity

Boot media

The services gateway boots from an alternate boot device.

Amber (minor)

Hardware components on the services gateway

The services gateway chassis temperature or chassis is too warm

Check the room temperature. See SRX100 Services Gateway Specifications.

Amber (minor)

The services gateway temperature is too high, either because of an internal overheating condition or because the maximum recommended room temperature has been exceeded.

The services gateway shuts down automatically in 4 minutes.