    Reinstalling the T320 SIBs

    To reinstall the SIBs (see Figure 1):

    1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
    2. Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB faceplate.
    3. Carefully align the sides of the SIB with the guides inside the chassis.
    4. Slide the SIB into the chassis, carefully ensuring that it is correctly aligned.
    5. Grasp both ejector handles and press them inward to seat the SIB.
    6. Tighten the captive screws on the ejector handles.
    7. Repeat the procedure for each of the remaining SIBs.

    Figure 1: Reinstalling a SIB

    Image g002406.gif