Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 

Replacing an M10i SFP

 

Small form-factor pluggables (SFPs) are transceivers that can be removed from a PIC (for more information, see M10i PICs Description).

SFPs are hot-insertable and hot-removable. Removing an SFP does not interrupt PIC functioning, but the removed SFP no longer receives or transmits data.

  1. Removing an M10i SFP

  2. Installing an M10i SFP

Removing an M10i SFP

Warning

Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

Caution

When handling fiber-optic transceivers and fiber-optic cable, observe the following precautions:

  • Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.

  • Do not bend fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  • Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.

To remove an SFP (see Figure 1):

  1. Place an electrostatic bag or antistatic mat on a flat, stable surface.
  2. Attach an ESD grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
  3. Label the cable connected to the SFP so that you can later reconnect it to the correct SFP.
  4. Disconnect the cable from the SFP. Immediately cover the transceiver and the end of the cable with a rubber safety cap.
  5. Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
  6. Pull the ejector handle away from the SFP faceplate to unseat the SFP from the PIC. Pull the SFP out of the PIC and place it on the antistatic mat or in the electrostatic bag.
Caution

After removing a transceiver from the chassis, wait at least 30 seconds before reinserting it or inserting a transceiver into a different slot.

Figure 1: Small Form-Factor Pluggable (SFP)
Small Form-Factor Pluggable
(SFP)

Installing an M10i SFP

Warning

Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

Caution

When handling fiber-optic transceivers and fiber-optic cable, observe the following precautions:

  • Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.

  • Do not bend fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  • Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.

To install a replacement SFP (see Figure 2):

  1. Attach an ESD grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
  2. Verify that a rubber safety cap covers the SFP transceiver, installing one if necessary.
  3. Orient the SFP over the port in the PIC so that the connector end will enter the slot first and the SFP connector faces the appropriate direction:
    • If the PIC has ten SFP ports, the ports are arranged in two columns. The SFP connector faces to the right for ports in the left column, and to the left for ports in the right column.

    • If the PIC has one or two SFP ports, the SFP connector faces to the left on platforms in which FPCs install vertically in the chassis, and faces upward on platforms in which FPCs install horizontally in the chassis.

  4. Slide the SFP into the slot. If there is resistance, remove the SFP and flip it so that the connector faces the other direction.
  5. Remove the rubber safety cap from the transceiver and the end of the cable, and insert the cable into the transceiver.
  6. Arrange the cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
  7. Verify that the status LEDs on the PIC faceplate indicate that the SFP is functioning correctly (there is an LED for each SFP port). For more information about the PIC LEDs, see the M10i Multiservice Edge Router Interface Module Reference. You can also verify PIC functioning by issuing the show chassis fpc pic-status command described in Maintaining the M10i PICs and PIC Cables.
Figure 2: Small Form-Factor Pluggable (SFP)
Small Form-Factor Pluggable
(SFP)