    Replacing an M7I AC Power Cord

    To replace the power cord for an AC power supply:

    1. Locate a replacement power cord with the type of plug appropriate for your geographical location (see M7i Router AC Power, Connection, and Power Cord Specifications).
    2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. Verify that the router is attached to a proper earth ground.
    3. Press the power switch on the power supply faceplate to the OFF (O) position.
    4. Unplug the power cord from the appliance inlet on the faceplate and from the power source receptacle.
    5. Insert the appliance coupler end of the replacement power cord into the appliance inlet on the power supply faceplate and insert the plug into an AC power source receptacle. Verify that the power cord does not block access to router components or drape where people could trip on it.
    6. Press the power switch on the power supply faceplate to the ON ( |) position. When the power supply has powered on successfully, the green OUTPUT OK LED lights steadily.