    Replacing a JCS1200 Network Clock Filler

    Removing a JCS1200 Network Clock Filler

    Figure 1 shows how to remove and install a network clock filler.

    Figure 1: Removing and Installing a JCS1200 Network Clock Filler

    Removing and Installing
a JCS1200 Network Clock Filler

    To remove a network clock filler (see Figure 1):

    1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
    2. Pull the release handle to the open position. The network clock filler moves out of the bay approximately 0.25 in. (0.6 cm).
    3. Slide the network clock filler out of the bay.

    Installing a JCS1200 Network Clock Filler

    Figure 2 shows how to remove and install a network clock filler.

    Figure 2: Removing and Installing a JCS1200 Network Clock Filler

    Removing and
Installing a JCS1200 Network Clock Filler

    To install a network clock filler (see Figure 2):

    1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
    2. Make sure that the release handle on the network clock filler is in the open position.
    3. Slide the network clock filler into the module bay until it stops.
    4. Push the release handle to the closed position.

    Published: 2013-01-30