    Replacing a JCS1200 Management Module Filler Tray

    Removing a JCS1200 Management Module Filler Tray

    Figure 1 shows how to remove and install a management module filler tray.

    Figure 1: Removing and Installing a JCS1200 Management Module Filler Tray

    Removing and
Installing a JCS1200 Management Module Filler Tray

    To remove a management module filler tray (see Figure 1):

    1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
    2. Remove the management module or filler from the management module bay (see Removing a JCS1200 Management Module or Module Filler).
    3. Pull the management module filler tray release handle to the open position. The filler tray moves out of the bay approximately 0.25 in. (0.6 cm).
    4. Slide the filler tray out of the bay.

    Installing a JCS1200 Management Module Filler Tray

    To install a management module filler tray:

    1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
    2. Remove the management module filler and management module tray filler.
    3. Make sure that the release handle on the filler tray is in the open position.
    4. Slide the filler tray into the management module bay until it stops.
    5. Push the filler tray release handle to the closed position.
    6. Install a management module or filler (see Installing a JCS1200 Management Module or Module Filler).

    Published: 2013-01-30