Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    Connecting a T320, T640, or T1600 Router to the JCS1200 Platform

    After you replace the CBs with T-CBs, you connect each T-CB on the T Series router to each switch module on the JCS1200 platform. Figure 1 shows the location of the switch modules on the JCS1200 platform.

    Figure 1: Location of Switch Modules on the JCS1200 Platform

    Location of Switch
Modules on the JCS1200 Platform

    To connect the T-CBs (see Figure 2):

    1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
    2. Plug an ETH adapter into the top RJ-45 port (labeled 1) of switch module 1 on the JCS1200 platform.
    3. Connect one end of a UTP Category 5 cable to the ETH adapter.
    4. Plug the other end of the cable into the port labeled CIP on T-CB-0. Dress the cable appropriately.

      Note: The RJ-45 port labeled AUX on a T-CB is reserved for future use.

    5. If you installed a redundant switch module into switch module bay 2:
      1. Plug an ETH adapter into the top RJ-45 port (labeled 1) of switch module 2 on the JCS1200 platform.
      2. Connect one end of a UTP Category 5 cable to the ETH adapter.
      3. Plug the other end of the cable into the port labeled CIP on T-CB-1. Dress the cable appropriately.

      Figure 2: Connecting the JCS1200 Platform to a T320, T640, or T1600 Router

      Connecting the JCS1200 Platform
to a T320, T640, or T1600 Router
    6. Repeat 2 through 5 to connect up to two additional T Series routers to RJ-45 ports labeled 2 and 3 on the JCS1200 switch module.

      Note: To connect more than one router, each router must run Junos OS Release 9.2 or later.

    Note: A switch module has six external 1000Base-T Ethernet ports for 10/100/1000 Mbps connections to external Ethernet devices, such as backbones, end stations, and servers. These ports are identified as EXT1, EXT2, EXT3, EXT4, EXT5, and EXT6 in the switch configuration menus and are labeled 1 through 6 (from top to bottom) on the JCS1200 switch module.

    Note: The connections between the switch modules and the T-CBs are proprietary Ethernet connections. Do not attempt to connect these components through a switch or hub.