Replacing a JCS 1200 Alarm Panel Module or Module Filler
Topics include:
Removing a JCS 1200 Alarm Panel Module or Module Filler
Figure 1 shows how to remove and install an alarm panel module.
Figure 1: Removing and Installing a JCS 1200 Alarm Panel Module
To remove an alarm panel module or module filler (see Figure 1):
- Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
- Pull the release handle to the open position. The module moves out of the bay approximately 0.25 in. (0.6 cm).
- Slide the alarm panel module out of the bay.
Installing a JCS 1200 Alarm Panel Module or Module Filler
Figure 2 shows how to remove and install an alarm panel module.
Figure 2: Removing and Installing a JCS 1200 Alarm Panel Module
To install an alarm panel module or module filler (see Figure 2):
- Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
- Make sure that the release handle on the alarm panel module is in the open position.
- Slide the alarm panel module into the alarm panel module bay until it stops.
- Push the release handle to the closed position.