Reinstalling Fan Trays After Installing the SRX5800 Services Gateway Chassis

 

To reinstall the fan trays (see Figure 1 and Figure 2):

  1. Attach an ESD grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  2. Grasp the fan tray on each side and insert it straight into the chassis. Note the correct orientation by the "this side up" label on the top surface of the fan tray.
  3. Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
  4. Lower the standard cable manager back into position, if necessary.
Figure 1: Installing an Upper Fan Tray
Installing
an Upper Fan Tray
Figure 2: Installing a Lower Rear Fan Tray
Installing
a Lower Rear Fan Tray