Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 

Connecting to the CLI at the User End for the SRX210 Services Gateway

 

To remotely connect to the CLI through a dial-up modem connected to the console port on the services gateway:

  1. Connect a modem at your remote location to a management device such as a PC or laptop computer.
  2. Start your asynchronous terminal emulation application (such as Microsoft Windows HyperTerminal) on the PC or laptop computer.
  3. Select the COM port to which the modem is connected (for example, COM1).
  4. Configure the port settings shown in Table 1.

    Table 1: Port Settings for Connecting to the CLI at User End

    Port Setting

    Value

    Bits per second

    9600

    Data bits

    8

    Parity

    None

    Stop bits

    1

    Flow control

    None

  5. In the HyperTerminal window, enter AT.

    An OK response verifies that the modem can communicate successfully with the COM port on the PC or laptop.

    For more information on the AT commands, see Administration Guide for Security Devices.

  6. Dial the modem that is connected to the console port on the services gateway by entering ATDT remote-modem-number. For example, if the number of the modem connected to the console port on the services gateway is 0013033033030, enter ATDT 0013033033030.

    The services gateway login prompt appears.

  7. Log in as the user root. No password is required at initial connection, but you must assign a root password before committing any configuration settings.