SRX3400 Services Gateway AC Power Cord Specifications

 

Each AC power supply has a single AC appliance inlet located on the power supply that requires a dedicated AC power feed and a dedicated 15 A (250 VAC) circuit breaker. Most sites distribute power through a main conduit that leads to frame-mounted power distribution panels, one of which can be located at the top of the rack that houses the services gateway. An AC power cord connects each power supply to the power distribution panel.

The services gateway is not shipped with AC power cords, you must order them separately using the model number shown in Table 1. The services gateway uses detachable AC power cords with C19 appliance couplers at the socket end as described by International Electrotechnical Commission (IEC) standard 60320. The plug end of the power cord fits into the power source receptacle that is standard for your geographical location.

Table 1 provides specifications and Figure 1 depicts the plug on the AC power cord available for each country or region.

Table 1: AC Power Cord Specifications

Country

Model Number

Electrical Specification

Plug Type

Australia/New Zealand

CBL-M-PWR-RA-AU

240 VAC, 50 Hz AC

SAA/3/15

China

CBL-M-PWR-RA-CH

220 VAC, 50 Hz AC

CH2-16P

Continental Europe (except Denmark, Italy, Switzerland, and United Kingdom)

CBL-M-PWR-RA-EU

220 or 230 VAC, 50 Hz AC

CEE 7/7

Italy

CBL-M-PWR-RA-IT

230 VAC, 50 Hz AC

CEI 23-16/VII

Japan

CBL-PWR-RA-JP15

125 VAC, 50 or 60 Hz AC

JIS 8303

CBL-M-PWR-RA-JP

220 VAC, 50 or 60 Hz AC

NEMA L6-20P

North America

CBL-PWR-RA-US15

125 VAC, 60 Hz AC

NEMA 5-15P

CBL-PWR-RA-TWLK-US15

125 VAC, 60 Hz AC

NEMA L5-15P

CBL-M-PWR-RA-US

250 VAC, 60 Hz AC

NEMA 6-20

CBL-M-PWR-RA-TWLK-US

250 VAC, 60 Hz AC

NEMA L6-20P

United Kingdom

CBL-M-PWR-RA-UK

240 VAC, 50 Hz AC

BS89/13

Figure 1: AC Plug Types
AC Plug Types
Warning

The AC power cord for the services gateway is intended for use with the services gateway only and not for any other use.

Note

In North America, AC power cords must not exceed 4.5 m (approximately 14.75 ft) in length, to comply with National Electrical Code (NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical Code (CEC) Section 4-010(3). The cords listed in Table 1 are in compliance.

For information about the AC power supply, including a description of components, see SRX3400 Services Gateway AC Power Supply Overview. For instructions on connecting the power cord during initial installation, see Connecting the SRX3400 Services Gateway to an AC Power Source. For instructions on replacing the AC power cables, see Replacing AC Power Supply Cables on the SRX3400 Services Gateway.