[an error occurred while processing this directive][an error occurred while processing this directive]

Management Port Connector Pinout Information for an EX Series Switch

The management port on an EX Series switch uses an RJ-45 connector to connect to a management device for out-of-band management.

The port uses an autosensing RJ-45 connector to support a 10/100/1000Base-T connection. Two LEDs on the port indicate link/activity on the port and the administrative status of the port. See Management Port LEDs in EX Series Switches.

Table 1 provides the pinout information of the RJ-45 connector. An RJ-45 cable, with a connector attached, is supplied with the switch.

Table 1: EX Series Switches Management Port Connector Pinout Information

Pin

Signal

Description

1

TRP1+

Transmit/receive data pair 1

2

TRP1-

Transmit/receive data pair 1

3

TRP2+

Transmit/receive data pair 2

4

TRP3+

Transmit/receive data pair 3

5

TRP3-

Transmit/receive data pair 3

6

TRP2-

Transmit/receive data pair 2

7

TRP4+

Transmit/receive data pair 4

8

TRP4-

Transmit/receive data pair 4


Published: 2009-12-15

[an error occurred while processing this directive]