    MX80 Router Environmental Specifications

    Table 1 specifies the environmental specifications required for normal router operation. In addition, the site should be as dust-free as possible.

    Table 1: Router Environmental Specifications

    Description

    Value

    Altitude

    No performance degradation to 10,000 ft (3048 m)

    Relative humidity

    Normal operation ensured in relative humidity range of 5% to 90%, noncondensing

    Temperature

    Normal operation ensured in temperature range of 32°F (0°C) to 104°F (40°C)

    Nonoperating storage temperature in shipping container: –40°F (–40°C) to 158°F (70°C)

    Seismic

    Designed to meet Telcordia Technologies Zone 4 earthquake requirements

    Maximum thermal output

    1705 BTU/hour (500 W)

    Note: Install the router only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical Code, ANSI/NFPA 70.