    Table 1 lists the electrical specifications for the JCS1200 alarm panel interface connector.

    Table 1: JCS1200 Alarm Panel Interface Connector Electrical Specifications

    Item

    Specification

    Outputs

    Voltage range

    0 V DC to –100 V DC (maximum current 0.3 A at 100 V DC)

    Current range

    0 A to 1 A (maximum voltage 30 V DC at 1 A)

    Worst-case VA

    1 A at –30 V DC (30 VA maximum) indefinitely

    Inputs

    Voltage range

    0 V DC to –100 V DC (including transients)

    Differential input voltage

    3 V DC to 72 V DC

    Reset Input Activation

    Pulse width

    200 ms (minimum) to 300 ms

    Note: The reset input resets only the state of the relay contact. The chassis alarm status does not change.