    SRX3600 Services Gateway AC Power Supply Electrical Specifications

    Table 1 lists the AC power supply electrical specifications.

    Table 1: AC Power Supply Electrical Specifications

    Parameter

    Specification

    Maximum output power

    1000 W (110 VAC input)

    1200 W (220 VAC input)

    AC input voltage

    100-127 V / 200-240 V

    AC input line frequency

    50 / 60 Hz

    AC input current rating

    12.0 A @ 100-127 V / 7 A @ 200-240 V

    Each AC power supply faceplate displays a single LED to indicate the status of the power supply (see Table 2).

    Table 2: AC Power Supply LED

    Color

    Status

    Condition Indicated

    Green

    On steadily

    AC input voltage is present, and both main 12V output and standby 3.3V output are enabled and healthy.

    Blinking

    AC input voltage is present, standby 3.3V output is on, but the main 12V output is disabled. This condition usually indicates that the services gateway has been powered off at the Power button on the SFB front panel. It might also indicate that either the SFB or the Routing Engine has been removed from the services gateway.

    Amber

    On steadily

    The power supply has detected one or more of the following faults:

    • Power supply fan failure
    • Power supply over-temperature condition
    • Over-current or under-voltage condition on the standby 3.3V output

    Blinking

    The power supply has detected one or more of the following faults:

    • Under-voltage condition on the 12V output
    • Over-voltage condition on the 12V output
    • Over-current condition on the 12V output