    Preventing Electrostatic Discharge Damage to the SRX3600 Services Gateway

    Many services gateway hardware components are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets. Observe the following guidelines to minimize the potential for electrostatic discharge (ESD) damage, which can cause intermittent or complete component failures:

    • Always use an ESD wrist strap or ankle strap, and verify that it is in direct contact with your skin.

      Caution: For safety, periodically check the resistance value of the ESD strap. The measurement should be in the range of 1 to 10 megaohms.

    • When handling any component that is removed from the chassis, verify that the equipment end of your ESD strap is attached to one of the ESD points on the chassis, which are shown in Figure 1 and Figure 2.

      Figure 1: ESD Point on Front of SRX3600 Services Gateway

      ESD Point on Front of SRX3600
Services Gateway

      Figure 2: ESD Point on Rear of SRX3600 Services Gateway

      ESD Point on Rear of SRX3600
Services Gateway
    • Avoid contact between the component and your clothing. ESD voltages emitted from clothing can still damage components.
    • When removing or installing a component, always place it component-side up on an antistatic surface, in an antistatic card rack, or in an electrostatic bag (see Figure 3). If you are returning a component, place it in an electrostatic bag before packing it.

    Figure 3: Placing a Component into an Electrostatic Bag

    Placing a Component into
an Electrostatic Bag