Troubleshooting Using the T1600 Chassis and Interface Alarm Messages

When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on the craft interface as appropriate, trips the corresponding alarm relay contact on the CIP, and reports the cause of the alarm in the craft interface LCD. To view a more detailed description of the alarm cause, issue the show chassis alarms CLI command:


user@host> show chassis alarms

There are two classes of alarm messages:

  • Chassis alarms—Indicate a problem with a chassis component such as the cooling system or power supplies, as described in Table 1.
  • Interface alarms—Indicate a problem with a specific network interface, as described in Table 2.

In both Table 1 and Table 2, the text in the column labeled “LCD Message” appears in the LCD. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.

Table 1: T1600 Chassis Alarm Messages

Component

Alarm Type

LCD Display Message

CLI Message

Fans

Red

Fan Failure

fan-name Failure

Fans Missing

Too many fans missing or failing

Yellow

Fan Removed

fan-name Removed

Temperature sensors

Red

Temperature Hot

Temperature Hot

Sensor Failure

Temperature sensor failure

Yellow

Temperature Warm

Temperature Warm

Power supplies

Red

PEM pem-number Over Temp

PEM pem-number Over Temperature

PEM pem-number Output Fail

PEM pem-number Output Failure

PEM pem-number Input Fail

PEM pem-number Input Failure

Yellow

PEM pem-number Removed

PEM pem-number Removed

SIBs

Red

SIB sib-number Failure

SIB sib-number Fault

SIB sib-number Removed

SIB sib-number Absent

Yellow

Spare SIB Failure

Spare SIB Fault

Spare SIB Removed

Spare SIB Absent

Check SIB

Check SIB

Host subsystems

Red

Host host-number Removed

Host host-number Removed

Yellow

Host host-number Failure

Host host-number Failure

T-CB

Red

CB cb-number Removed

CB cb-number Removed

CB cb-number Failure

CB cb-number Failure

Yellow

CB cb-number Ethernet Switch Failure

CB cb-number Ethernet Switch Failure

SCG

SCG SCG-number Failure

RED ALARMSCG SCG-number Failure

SCG SCG-number Removed

RED ALARMSCG SCG-number Failure

SCG SCG-number Not Online

YELLOW ALARMSCG SCG-number Not Online

Craft interface

Yellow

Craft Failure

Craft Failure

Table 2: SONET/SDH Interface Alarm Messages

LCD Message

CLI Message

interface-name so-x/x/x BERR-SD

interface-name so-x/x/x - SONET bit error rate defect

interface-name so-x/x/x BERR-SF

interface-name so-x/x/x - SONET bit error rate fault

interface-name so-x/x/x LAIS

interface-name so-x/x/x - SONET line AIS

interface-name so-x/x/x LOF

interface-name so-x/x/x - SONET loss of frame

interface-name so-x/x/x LOL

interface-name so-x/x/x - SONET loss of light

interface-name so-x/x/x LOP

interface-name so-x/x/x - SONET loss of pointer

interface-name so-x/x/x LOS

interface-name so-x/x/x - SONET loss of signal

interface-name so-x/x/x LRDI

interface-name so-x/x/x - SONET line remote defect indicator

interface-name so-x/x/x PAIS

interface-name so-x/x/x - SONET path AIS

interface-name so-x/x/x PLL

interface-name so-x/x/x - SONET PLL lock

interface-name so-x/x/x PMIS

interface-name so-x/x/x - SONET path mismatch

interface-name so-x/x/x PRDI

interface-name so-x/x/x - SONET path remote defect indicator

interface-name so-x/x/x REI

interface-name so-x/x/x - SONET remote error indicator

interface-name so-x/x/x SEF

interface-name so-x/x/x - SONET severely errored frame

interface-name so-x/x/x UNEQ

interface-name so-x/x/x - SONET unequipped