Troubleshooting Using the T1600 Chassis and Interface Alarm
Messages
When the Routing Engine detects an alarm condition, it lights
the red or yellow alarm LED on the craft interface as appropriate,
trips the corresponding alarm relay contact on the CIP, and reports
the cause of the alarm in the craft interface LCD. To view a more
detailed description of the alarm cause, issue the show chassis alarms CLI command:
user@host> show chassis alarms
There are two classes of alarm messages:
- Chassis alarms—Indicate a problem with a chassis
component such as the cooling system or power supplies, as described
in Table 1.
- Interface alarms—Indicate a problem with a specific
network interface, as described in Table 2.
In both Table 1 and Table 2, the text in the column labeled
“LCD Message” appears in the LCD. The text in the column
labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 1: T1600 Chassis Alarm Messages
Component
|
Alarm Type
|
LCD Display Message
|
CLI Message
|
Fans
|
Red
|
Fan Failure
|
fan-name Failure
|
Fans Missing
|
Too many fans missing or failing
|
Yellow
|
Fan Removed
|
fan-name Removed
|
Temperature sensors
|
Red
|
Temperature Hot
|
Temperature Hot
|
Sensor Failure
|
Temperature sensor failure
|
Yellow
|
Temperature Warm
|
Temperature Warm
|
Power supplies
|
Red
|
PEM pem-number Over Temp
|
PEM pem-number Over
Temperature
|
PEM pem-number Output Fail
|
PEM pem-number Output
Failure
|
PEM pem-number Input Fail
|
PEM pem-number Input
Failure
|
Yellow
|
PEM pem-number Removed
|
PEM pem-number Removed
|
SIBs
|
Red
|
SIB sib-number Failure
|
SIB sib-number Fault
|
SIB sib-number Removed
|
SIB sib-number Absent
|
Yellow
|
Spare SIB Failure
|
Spare SIB Fault
|
Spare SIB Removed
|
Spare SIB Absent
|
Check SIB
|
Check SIB
|
Host subsystems
|
Red
|
Host host-number Removed
|
Host host-number Removed
|
Yellow
|
Host host-number Failure
|
Host host-number Failure
|
T-CB
|
Red
|
CB cb-number Removed
|
CB cb-number Removed
|
CB cb-number Failure
|
CB cb-number Failure
|
Yellow
|
CB cb-number Ethernet Switch
Failure
|
CB cb-number Ethernet Switch
Failure
|
SCG
|
SCG SCG-number Failure
|
RED ALARM—SCG SCG-number Failure
|
SCG SCG-number Removed
|
RED ALARM—SCG SCG-number Failure
|
SCG SCG-number Not
Online
|
YELLOW ALARM—SCG SCG-number Not
Online
|
Craft interface
|
Yellow
|
Craft Failure
|
Craft Failure
|
Table 2: SONET/SDH Interface Alarm Messages
LCD Message
|
CLI Message
|
interface-name so-x/x/x BERR-SD
|
interface-name so-x/x/x - SONET
bit error rate defect
|
interface-name so-x/x/x BERR-SF
|
interface-name so-x/x/x - SONET
bit error rate fault
|
interface-name so-x/x/x LAIS
|
interface-name so-x/x/x - SONET
line AIS
|
interface-name so-x/x/x LOF
|
interface-name so-x/x/x - SONET
loss of frame
|
interface-name so-x/x/x LOL
|
interface-name so-x/x/x - SONET
loss of light
|
interface-name so-x/x/x LOP
|
interface-name so-x/x/x - SONET
loss of pointer
|
interface-name so-x/x/x LOS
|
interface-name so-x/x/x - SONET
loss of signal
|
interface-name so-x/x/x LRDI
|
interface-name so-x/x/x - SONET
line remote defect indicator
|
interface-name so-x/x/x PAIS
|
interface-name so-x/x/x - SONET
path AIS
|
interface-name so-x/x/x PLL
|
interface-name so-x/x/x - SONET
PLL lock
|
interface-name so-x/x/x PMIS
|
interface-name so-x/x/x - SONET
path mismatch
|
interface-name so-x/x/x PRDI
|
interface-name so-x/x/x - SONET
path remote defect indicator
|
interface-name so-x/x/x REI
|
interface-name so-x/x/x - SONET
remote error indicator
|
interface-name so-x/x/x SEF
|
interface-name so-x/x/x - SONET
severely errored frame
|
interface-name so-x/x/x UNEQ
|
interface-name so-x/x/x - SONET
unequipped
|
Published: 2009-09-30