Table 1: M320 Chassis Alarm Messages

Component

Alarm Type

LCD Display Message

CLI Message

Fans

Red

Fan Failure

fan-name Failure

Fans Missing

Too many fans missing or failing

Yellow

Fan Removed

fan-name Removed

Temperature sensors

Red

Temperature Hot

Temperature Hot

Sensor Failure

Temperature sensor failure

Yellow

Temperature Warm

Temperature Warm

Power supplies

Red

PEM pem-number Over Temp

PEM pem-number Over Temperature

PEM pem-number Output Fail

PEM pem-number Output Failure

PEM pem-number Input Fail

PEM pem-number Input Failure

Yellow

PEM pem-number Removed

PEM pem-number Removed

SIBs

Red

SIB sib-number Failure

SIB sib-number Fault

SIB sib-number Removed

SIB sib-number Absent

Yellow

Spare SIB Failure

Spare SIB Fault

Spare SIB Removed

Spare SIB Absent

Check SIB

Check SIB

Host subsystems

Red

Host host-number Removed

Host host-number Removed

Yellow

Host host-number Failure

Host host-number Failure

CB

Red

CB cb-number Removed

CB cb-number Removed

CB cb-number Failure

CB cb-number Failure

Yellow

CB cb-number Ethernet Switch Failure

CB cb-number Ethernet Switch Failure

Craft interface

Yellow

Craft Failure

Craft Failure

Table 2: SONET/SDH Interface Alarm Messages

LED Display Message

CLI Message

interface-name so-x/x/x BERR-SD

interface-name so-x/x/x - SONET bit error rate defect

interface-name so-x/x/x BERR-SF

interface-name so-x/x/x - SONET bit error rate fault

interface-name so-x/x/x LAIS

interface-name so-x/x/x - SONET line AIS

interface-name so-x/x/x LOF

interface-name so-x/x/x - SONET loss of frame

interface-name so-x/x/x LOL

interface-name so-x/x/x - SONET loss of light

interface-name so-x/x/x LOP

interface-name so-x/x/x - SONET loss of pointer

interface-name so-x/x/x LOS

interface-name so-x/x/x - SONET loss of signal

interface-name so-x/x/x LRDI

interface-name so-x/x/x - SONET line remote defect indicator

interface-name so-x/x/x PAIS

interface-name so-x/x/x - SONET path AIS

interface-name so-x/x/x PLL

interface-name so-x/x/x - SONET PLL lock

interface-name so-x/x/x PMIS

interface-name so-x/x/x - SONET path mismatch

interface-name so-x/x/x PRDI

interface-name so-x/x/x - SONET path remote defect indicator

interface-name so-x/x/x REI

interface-name so-x/x/x - SONET remote error indicator

interface-name so-x/x/x SEF

interface-name so-x/x/x - SONET severely errored frame

interface-name so-x/x/x UNEQ

interface-name so-x/x/x - SONET unequipped