TX Matrix Chassis and Interface Alarm Messages Overview

 

TX Matrix Chassis and Interface Alarm Messages Description

When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on the craft interface as appropriate, trips the corresponding alarm relay contact on the TX-CIP, and reports the cause of the alarm in the craft interface LED display. To view a more detailed description of the alarm cause, issue the show chassis alarms scc CLI command:

user@host> show chassis alarms scc

To display all alarms in the routing matrix, issue the show chassis alarms command without the scc option.

TX Matrix Chassis Alarm Messages

TX Matrix chassis alarms Indicate a problem with a TX Matrix chassis component such as the cooling system or power supplies, as described in Table 1.

Note

The text in the column labeled ”Craft Interface Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.

Table 1: TX Matrix Chassis Alarm Messages

Component

Alarm Type

Craft Interface Message

CLI Message

Fans

Red

Fan Failure

fan-name Failure

Fans Missing

Too many fans missing or failing

Yellow

Fan Removed

fan-name Removed

Temperature sensors

Red

Temperature Hot

Temperature Hot

Sensor Failure

Temperature sensor failure

Yellow

Temperature Warm

Temperature Warm

Power supplies

Red

PEM pem-number Over Temp

PEM pem-number Over Temperature

PEM pem-number Output Fail

PEM pem-number Output Failure

PEM pem-number Input Fail

PEM pem-number Input Failure

Yellow

PEM pem-number Removed

PEM pem-number Removed

TX-SIBs

Red

SIB sib-number Failure

SIB sib-number Fault

SIB sib-number Removed

SIB sib-number Absent

Yellow

Spare SIB Failure

Spare SIB Fault

Spare SIB Removed

Spare SIB Absent

Check SIB

Check SIB

Host subsystems

Red

Host host-number Removed

Host host-number Removed

Yellow

Host host-number Failure

Host host-number Failure

Control Board

Red

CB cb-number Removed

CB cb-number Removed

CB cb-number Failure

CB cb-number Failure

Yellow

CB cb-number Ethernet Switch Failure

CB cb-number Ethernet Switch Failure

Craft interface

Yellow

Craft Failure

Craft Failure

T640 Router Alarm Messages

T640 router alarms indicate a problem with a T640 router (LCC) in the routing matrix, as described in Table 2. For a list of additional alarm messages that apply only to the T640 router, see the T640 Core Router Hardware Guide.

Note

The text in the column labeled ”Craft Interface Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.

Table 2: T640 Router Alarm Messages

Component

Alarm Type

Craft Interface Message

CLI Message

Fans

Red

T640 Rear Fan Tray in LCC

T640 Rear Fan Tray in LCC

T640 router

Red

LCC lcc-number Hard Errors

LCC lcc-number Hard Errors

LCC lcc-number Major Errors

LCC lcc-number Major Errors

No LCC Online

No LCC Online

LCC lcc-number Not Online

LCC lcc-number Not Online

Yellow

LCC lcc-number Soft Errors

LCC lcc-number Soft Errors

LCC lcc-number Minor Errors

LCC lcc-number Minor Errors

SONET/SDH Interface Alarm Messages

Interface alarms indicate a problem with a specific network interface. For example, Table 3 lists the alarm messages for a SONET/SDH interface. These messages apply only to a T640 router in a routing matrix. For more information about interface alarms, see the T640 Core Router Interface Module Reference.

Note

The text in the column labeled ”Craft Interface Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.

Table 3: SONET/SDH Interface Alarm Messages

Craft Interface Message

CLI Message

interface-name so-x/x/x BERR-SD

interface-name so-x/x/x - SONET bit error rate defect

interface-name so-x/x/x BERR-SF

interface-name so-x/x/x - SONET bit error rate fault

interface-name so-x/x/x LAIS

interface-name so-x/x/x - SONET line AIS

interface-name so-x/x/x LOF

interface-name so-x/x/x - SONET loss of frame

interface-name so-x/x/x LOL

interface-name so-x/x/x - SONET loss of light

interface-name so-x/x/x LOP

interface-name so-x/x/x - SONET loss of pointer

interface-name so-x/x/x LOS

interface-name so-x/x/x - SONET loss of signal

interface-name so-x/x/x LRDI

interface-name so-x/x/x - SONET line remote defect indicator

interface-name so-x/x/x PAIS

interface-name so-x/x/x - SONET path AIS

interface-name so-x/x/x PLL

interface-name so-x/x/x - SONET PLL lock

interface-name so-x/x/x PMIS

interface-name so-x/x/x - SONET path mismatch

interface-name so-x/x/x PRDI

interface-name so-x/x/x - SONET path remote defect indicator

interface-name so-x/x/x REI

interface-name so-x/x/x - SONET remote error indicator

interface-name so-x/x/x SEF

interface-name so-x/x/x - SONET severely errored frame

interface-name so-x/x/x UNEQ

interface-name so-x/x/x - SONET unequipped