Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 

TX Matrix Plus TXP-F13-3D SIB LEDs

 

The TXP-F13-3D status LEDs (Figure 1) are located below the SIB button. Table 1 describes the functions of these LEDs.

Figure 1: TXP-F13-3D SIB LEDs
TXP-F13-3D SIB LEDs

Table 1: TXP-F13-3D SIB LEDs

Label

Color

State

Description

ACTIVE

Green

On steadily

TXP-F13-3D SIB is in active mode and actively passing traffic.

Off

TXP-F13-3D SIB is either offline or not actively passing traffic.

OK

Green

On steadily

TXP-F13-3D SIB is functioning normally.

Off

TXP-F13-3D SIB is offline or not seated properly.

FAIL

Red

On steadily

TXP-F13 SIB-3D has failed.

Off

No faults have been detected for the TXP-F13-3D SIB.

The port LEDs are located beneath the ports. Table 2 describes the functions of these LEDs.

Table 2: TXP-F13-3D SIB Port LEDs

Label

Color

State

Description

LINK

Green

On steadily

The link between the TXP-F13-3D SIB port and the TXP-LCC-3D SIB port has been established successfully.

Blinking

The link between the TXP-F13-3D SIB port and the loopback connector has been established successfully.

Yellow

On steadily

The link is being established.

Blinking

The switching plane cable might be connected to either the wrong TXP-LC-3D SIB port or wrong TXP-FI3-3D port.

Red

On steadily

The link between the TXP-F13-3D SIB port and the TXP-LCC-3D SIB port failed. There might be a hardware problem, or the fiber-optic port or cable might need to be cleaned.

Off

The cable is not connected on both sides, or either the TXP-F13-3D SIB or TXP-LCC-3D SIB is powered off.

CBL

Green

On steadily

Full optical power is being received.

 

Yellow

On steadily

Diminished optical power is being received. The switching plane cable or the switching plane port might need cleaning, or the cable might be damaged.

Red

Off

Optical power has crossed operating thresholds. The switching plane cable is not connected to the TXP-FI3-3D SIB port, or not connected to the TXP-LCC-3D SIB port. If the cable is connected on both sides, the cable might be cut.

  

Off

-