Table 1: Chassis Component Alarm Conditions on QFX5120 Switches
Chassis Component | Alarm Condition | Alarm Severity | Remedy |
---|---|---|---|
Power supplies | A power supply is removed from the chassis. | Major (red) | Install a power supply in the empty slot. |
A power supply output has failed. | Major (red) | Check the power supply output connection. | |
A power supply has failed. | Major (red) | Replace the failed power supply. | |
An unknown power supply is installed. | Major (red) | Install a power supply recommended by Juniper Networks. | |
Mix of power supplies with different airflow directions. | Major (red) | Do not mix power supplies with different directions for the airflow in the same chassis. | |
Fan modules | Fan module is not installed. | Major (red) | Install the fan module. |
A fan module has failed. | Major (red) | Replace the fan module. | |
Mix of fan modules with different airflow directions. | Major (red) | Do not mix fan modules with different directions for the airflow in the same chassis. | |
Temperature | The temperature inside the chassis reaches the yellow or amber alarm limit. | Minor (yellow or amber) |
|
The temperature inside the chassis reaches the red alarm limit. | Major (red) |
| |
Management Ethernet interface | Management Ethernet link is down | Major (red) |
|
Routing Engine | Rescue configuration is not set. | Minor (yellow or amber) | Use the request system configuration rescue save command to set the rescue configuration. |
Feature usage requires a license or the license for the feature usage has expired. | Minor (yellow or amber) | Install the required license for the feature specified in the alarm. |