Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 

Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP (T640 Router)

 
Figure 1: 1-Port IQE PIC
1-Port IQE PIC
Figure 2: 4-Port IQE PIC (Type 2)
4-Port IQE PIC (Type 2)
Figure 3: 4-Port IQE PIC (Type 3)
4-Port IQE PIC (Type 3)
 

Software release

  • 1-port: Junos OS Release 9.3 and later (Type 1)

  • 4-port: Junos OS Release 9.4 and later (Type 2)

  • 4-port: Junos OS Release 10.0R2 and later (Type 3)

For information on which FPCs support these PICs, see T640 PIC/FPC Compatibility.

Description

  • One or four OC12/STM4 ports

  • SONET or SDH is configurable on a per-port granularity

  • SONET channelization (1-port PIC):

    • 1 OC12 channel

    • 4 OC3 channels

    • 12 DS3 channels

    • 336 DS1 channels

    • 1011 DS0 channels

  • SDH channelization (1-port PIC):

    • 1 STM4 channel

    • 4 STM1 channels

    • 12 E3 channels

    • 252 E1 channels

    • 12 DS3 channels (Junos OS Release 10.1 and later)

    • 336 DS1 channels (Junos OS Release 10.1 and later)

    • 1011 DS0 channels

  • SONET channelization (4-port PIC):

    • 4 OC12 channel

    • 16 OC3 channels

    • 48 DS3 channels

    • 672 DS1 channels

    • 974 DS0 channels

  • SDH channelization (4-port PIC):

    • 4 STM4 channel

    • 16 STM1 channels

    • 48 E3 channels

    • 504 E1 channels

    • 48 DS3 channels (Junos OS Release 10.1 and later)

    • 672 DS1 channels (Junos OS Release 10.1 and later)

    • 974 DS0 channels

  • Power requirement:

    • 1-port: 0.64 A @ –48 V (30.7 W)

    • 4-port: 1.08 A @ –48V (52 W)

  • Model number for 1-Port IQE PIC: PB-1CHOC12-STM4-IQE-SFP

    Model number for 4-Port IQE PIC: PB-4CHOC12-STM4-IQE-SFP

Hardware features

  • 1-port: Port is numbered 0.

  • 4-port: Ports are numbered:

    • Top row: 2 and 0 from left to right

    • Bottom row: 3 and 1 from left to right

Software features

  • Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection (RED), weighted random early detection (WRED)

  • Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for Routing Devices and EX9200 Switches for more information about class of service features.

  • Subrate and scrambling:

    • Digital Link/Quick Eagle

    • Kentrox

    • Larscom

    • ADTRAN

    • Verilink

  • Packet buffering, Layer 2 parsing

  • M13/C-bit parity encoding

  • DS3 far-end alarm and control (FEAC) channel support

  • Local line, remote line, and remote payload loopback testing

  • Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB

  • Dynamic, arbitrary channel configuration

  • Full bit error rate test (BERT)

  • Encapsulations:

    • Circuit cross-connect (CCC)

    • Translational cross-connect (TCC)

    • Extended Frame Relay for CCC and TCC

    • Flexible Frame Relay

    • Frame Relay

    • Frame Relay for CCC

    • Frame Relay for TCC

    • Frame Relay port CCC

    • High-Level Data Link Control (HDLC)

    • HDLC framing for CCC

    • HDLC framing for TCC

    • MPLS CCC

    • MPLS TCC

    • Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)

    • Point-to-Point Protocol (PPP)

    • PPP for CCC

    • PPP for TCC

  • Encapsulations available only for DS1:

    • Multilink Frame Relay end-to-end (MLFR FRF.15)

    • Multilink PPP (MLPPP)

    • PPP over Frame Relay

Cables and connectors

  • Duplex LC/PC connector (Rx and Tx); single-mode fiber

  • SONET/SDH OC12/STM4 fiber-optic SFP transceivers:

    • Short reach (model number: SFP-OC12-SR)

    • Intermediate reach (IR-1) (model number: SFP-OC12-IR)

    • Long reach (LR-1) (model number: SFP-OC12-LR)

    Optical interface specifications—see SONET/SDH OC12/STM4 Optical Interface Specifications

LEDs

One tricolor per port:

  • Off—Not enabled

  • Green—Online with no alarms or failures

  • Yellow—Online with alarms for remote failures

  • Red—Active with a local alarm; router has detected a failure

Alarms, errors, and events

  • SONET alarms:

    • Alarm indication signal—line (AIS-L)

    • Alarm indication signal—path (AIS-P)

    • Bit error rate—signal degrade (BERR-SD)

    • Bit error rate—signal fail (BERR-SF)

    • Loss of frame (LOF)

    • Loss of light (LOL)

    • Loss of pointer (LOP)

    • Loss of signal (LOS)

    • Payload label mismatch (PLM-P)

    • Remote defect indication—line (RDI-L)

    • Remote defect indication—path (RDI-P)

    • Remote error indication (REI)

    • Payload unequipped (unequipped STS at path level) (UNEQ-P)

    • Virtual container—alarm indication signal (VAIS)

    • Virtual container—loss of pointer (VLOP)

    • Virtual container—mismatch (VMIS)

    • Virtual container—remote defect indication (VRD1)

    • Virtual container—unequipped (VUNEQ)

  • SDH alarms:

    • Administrative unit alarm indication signal (AU-AIS)

    • Bit error rate—signal degrade (BERR-SD)

    • Bit error rate—signal fail (BERR-SF)

    • Bit interleaved parity (BIP) error B1, B2, B3

    • Higher order path—alarm indication signal (HP-AIS)

    • Higher order path—far-end receive failure (HP-FERF)

    • Higher order path—payload label mismatch (HP-PLM)

    • Higher order path—loss of pointer (HP-LOP)

    • Higher order path—remote defect indication (HP-RDI)

    • Higher order path—unequipped (HP-UNEQ)

    • Loss of frame (LOF)

    • Loss of light (LOL)

    • Loss of signal (LOS)

    • Multiplex section—alarm indication signal (MS-AIS)

    • Multiplex section—far-end receive failure (MS-FERF)

    • Multiplex section—remote defect indication (MS-RDI)

    • Multiplex section—remote error indication (MS-REI)

    • Phase lock loop (PLL)

    • Remote error indication (REI)

    • Severely errored frame (SEF)

    • Tributary unit—alarm indication signal (TU-AIS)

    • Tributary unit—loss of pointer (TU-LOP)

    • Tributary unit—mismatch (TU-MIS)

    • Tributary unit—remote defect indication (TU-RD1)

    • Tributary unit—unequipped (TU-UNEQ)

  • DS1 alarms:

    • Alarm indication signal (AIS)

    • Loss of frame (LOF)

    • Remote alarm indication signal (RAIS)

  • DS1 error detection:

    • Bursty errored seconds (BES)

    • CRC errors

    • Errored seconds (ES)

    • Line errored seconds (LES)

    • Loss of framing seconds (LOFS)

    • Severely errored seconds (SES)

    • Severely errored framing seconds (SEFS)

    • Unavailable seconds (UAS)

  • DS3 alarms:

    • Alarm indication signal (AIS)

    • Loss of frame (LOF)

    • Yellow alarm

  • DS3 error detection:

    • C-bit code violations (CCV)

    • C-bit errored seconds (CES)

    • C-bit severely errored framing seconds (CEFS)

    • CRC errors

    • Excessive zeros (EXZ)

    • Far-end block error (FEBE)

    • Far-end receive failure (FERF)

    • Line errored seconds (LES)

    • Parity bit (P-bit) code violations (PCV)

    • Parity bit (P-bit) errored seconds (PES)

    • Parity bit (P-bit) severely errored framing seconds (PSES)

    • Severely errored framing seconds (SEFS)

    • Unavailable seconds (UAS)

Instrumentation (counters)

  • Layer 2 per-queue and per-channel packet and byte counters