SONET/SDH OC192/STM64 PICs with XFP (T4000 Router)

 
Figure 1: 1-Port SONET/SDH OC192/STM64 PIC
1-Port SONET/SDH OC192/STM64 PIC
Figure 2: 4-Port SONET/SDH OC192/STM64 PIC
4-Port SONET/SDH OC192/STM64 PIC

Software Release

  • 1-port: Junos OS Release 12.1R2 and later (Type 3)

  • 4-port: Junos OS Release 12.1 and later (Type 4)

For information on which FPCs support this PIC, see T4000 PIC/FPC Compatibility.

Hardware Features

  • One or four OC192 ports

    Note

    Four OC192 links can be aggregated into one OC768 link or two OC256 links. The four fiber links should be on the same fiber path or the same fiber.

  • Power requirement:

    • 1-port (Type 3): 0.52 A @ 48 V (25 W)

    • 4-port (Type 4): 1.11 A @ 48 V (53.1 W)

  • Model number for 1-port SONET/SDH OC192/STM64 PIC: PC-1OC192-SON-XFP

  • Model number for 4-port SONET/SDH OC192/STM64 PIC: PD-4OC192-SON-XFP

  • Multiplexing and demultiplexing

  • Rate policing on input

  • Rate shaping on output

  • Packet buffering, Layer 2 parsing

Software Features

Table 1: Software Features Supported

Software Feature

T4000 First Supported Junos OS Release for Type 3 PIC

T4000 First Supported Junos OS Release for Type 4 PIC

Configuration of SONET or SDH framing on a per-port basis on the 4-port Type 4 PIC .

12.1R2

12.1R1

SONET/SDH framing

12.1R2

12.1R1

IEEE 802.3ad Link Aggregation

12.1R2

12.1R1

Alarm and event counting and detection

12.1R2

12.1R1

Dual-router automatic protection switching (APS)

12.1R2

12.1R1

Multiprotocol Label Switching (MPLS) fast reroute

12.1R2

12.1R1

Encapsulations:

  • Circuit cross-connect (CCC)

  • Translational cross-connect (TCC)

  • Frame Relay

  • High-Level Data Link Control (HDLC)

  • Point-to-Point Protocol (PPP)

12.1R2

12.1R1

Cables and Connectors

  • Duplex LC connector (Rx and Tx)

  • SONET/SDH OC192c/STM64 XFP transceivers:

    • Short reach (SR-1) (model number: XFP-10G-L-OC192-SR1)

    • Intermediate reach (IR-1) (model number: XFP-10G-E-OC192-IR2)

    • Long reach (LR-1) (model number: XFP-10G-Z-OC192-LR2)

    Optical interface specifications—see SONET/SDH OC192/STM64 Optical Interface Specifications

Note

To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.

LEDs

Table 2: 1-Port SONET/SDH OC192/STM64 PIC LEDs

Label

Color

State

Description

LINK STATUS LED

Off

Port is down.

Green

On steadily

Port is online. Link is established.

Table 3: 4-Port SONET/SDH OC192/STM64 PIC LEDs

Label

Color

State

Description

Port LEDs labeled PORT 0 through PORT 3, one tricolor LED per port

Off

Not enabled.

Green

On steadily

Online with no alarms or failures.

Yellow

On steadily

Online with alarms for remote failures.

Red

On steadily

Active with a local alarm; router has detected a failure.

One 768 over 192 LED

Off

Not enabled.

Green

On steadily

Online with no alarms or failures.

Yellow

On steadily

Online with alarms for remote failures.

Red

On steadily

Active with a local alarm; router has detected a failure.

Alarms, Errors, and Events

  • SONET alarms:

    • Alarm indication signal—line (AIS-L)

    • Alarm indication signal—path (AIS-P)

    • Bit error rate—signal degrade (BERR-SD)

    • Bit error rate—signal fail (BERR-SF)

    • Bit interleaved parity (BIP) error B1, B2, B3

    • Far-end bit error: remote error indication—line (REI-L), far-end line coding violations (CV-LFE)

    • Far-end bit error: remote error indication—path (REI-P), far-end path coding violations (CV-PFE)

    • Loss of frame (LOF)

    • Loss of pointer (LOP-P)

    • Loss of signal (LOS)

    • Payload label mismatch (PLM-P)

    • Payload unequipped (unequipped STS at path level) (UNEQ-P)

    • Remote defect indication—line (RDI-L)

    • Remote defect indication—path (RDI-P)

  • SDH alarms:

    • Administrative unit alarm indication signal (AU-AIS)

    • Bit error rate signal degrade (BERR-SD)

    • Bit error rate signal fail (BERR-SF)

    • Bit interleaved parity (BIP) error B1, B2, B3

    • Higher order path—payload label mismatch (HP-PLM)

    • Higher order path—loss of pointer (HP-LOP)

    • Higher order path—remote defect indication (HP-RDI)

    • Higher order path—unequipped (HP-UNEQ)

    • Loss of frame (LOF)

    • Loss of signal (LOS)

    • Multiplex section—alarm indication signal (MS-AIS)

    • Multiplex section—remote defect indication (MS-RDI)

    • Multiplex section—remote error indication (MS-REI)

  • Error detection:

    • Errored seconds (ES-S, ES-L, ES-P)

    • Far-end errored seconds (ES-LFE, ES-PFE)

    • Far-end severely errored seconds (SES-LFE, SES-PFE)

    • Far-end unavailable seconds (UAS-LFE, UAS-PFE)

    • Severely errored framing (SEF)

    • Severely errored framing seconds (SEFS-S)

    • Severely errored seconds (SES-S, SES-L, SES-P)

    • Unavailable seconds (UAS-L, UAS-P)