SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP (T4000 Router)
![]() | ![]() |
Software Release
Junos OS Release 12.1R2 ander later
Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see T4000 PIC/FPC Compatibility.
Hardware Features
1-port: Rate-selectable using one of the following rates:
1-port OC3/STM1
1-port OC12/STM4
1-port OC12c/STM4c
4-port: Rate-selectable using one of the following rates:
1-port OC12/STM4
1-port OC48/STM16
1-port OC48c/STM16c
4-port OC3c/STM1c
4-port OC12c/STM4c
Power requirement:
1-port: 0.20 A @ 48 V (9.5 W)
4-port: 0.40 A @ 48 V (19 W)
Model number for 1-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC: PB-1OC12-SON-SFP
Model number for 4-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC: PB-4OC3-4OC12-SON-SFP
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
Software Features
Table 1: Software Features Supported
Software Feature | T4000 First Supported Junos OS Release for 1-port PIC | T4000 First Supported Junos OS Release for 4-port PIC |
---|---|---|
Optical diagnostics and related alarms | 12.1R2 | 12.2R2 |
Per-port SONET/SDH framing | 12.1R2 | 12.2R2 |
Link aggregation | 12.1R2 | 12.2R2 |
Alarm and event counting and detection | 12.1R2 | 12.2R2 |
Dual-router automatic protection switching (APS) | 12.1R2 | 12.2R2 |
Multiprotocol Label Switching (MPLS) fast reroute | 12.1R2 | 12.2R2 |
Encapsulations:
| 12.1R2 | 12.2R2 |
Cables and Connectors
You can install any transceiver supported by the PIC. For information about installing and removing transceivers.
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 small form-factor pluggable (SFP) transceivers:
Multimode (model number: SFP-OC3-SR)
Intermediate reach (IR-1) (model number: SFP-OC3-IR)
Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see SONET/SDH OC3/STM1 Optical Interface Specifications
SONET/SDH OC12/STM4 small form-factor pluggable (SFP) transceivers:
Short reach (model number: SFP-OC12-SR)
Intermediate reach (IR-1) (model number: SFP-OC312-IR)
Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see SONET/SDH OC12/STM4 Optical Interface Specifications
To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
LEDs
Table 2: SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP LEDs
Label | Color | State | Description |
---|---|---|---|
One tricolor per port | — | Off | Not enabled. |
Green | On steadily | Online with no alarms or failures. | |
Yellow | On steadily | Online with alarms for remote failures. | |
Red | On steadily | Active with a local alarm; router has detected a failure. |
Alarms, Errors, and Events
SONET alarms:
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate—signal degrade (BERR-SD)
Bit error rate—signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1, B2, B3
Far-end bit error: remote error indication—line (REI-L), far-end line coding violations (CV-LFE)
Far-end bit error: remote error indication—path (REI-P), far-end path coding violations (CV-PFE)
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Payload label mismatch (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
SDH alarms:
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1, B2, B3
Higher order path—payload label mismatch (HP-PLM)
Higher order path—loss of pointer (HP-LOP)
Higher order path—remote defect indication (HP-RDI)
Higher order path—unequipped (HP-UNEQ)
Loss of frame (LOF)
Loss of signal (LOS)
Multiplex section—alarm indication signal (MS-AIS)
Multiplex section—remote defect indication (MS-RDI)
Multiplex section—remote error indication (MS-REI)
Error detection:
Errored seconds (ES-S, ES-L, ES-P)
Far-end errored seconds (ES-LFE, ES-PFE)
Far-end severely errored seconds (SES-LFE, SES-PFE)
Far-end unavailable seconds (UAS-LFE, UAS-PFE)
Severely errored framing (SEF)
Severely errored framing seconds (SEFS-S)
Severely errored seconds (SES-S, SES-L, SES-P)
Unavailable seconds (UAS-L, UAS-P)