Cables and connectors | Note:
To extend the life of the laser, when a PIC is not being
actively used with any valid links, take the PIC offline until you
are ready to establish a link to another device. For information about
taking a PIC offline, see the request chassis pic offline command in the Junos System Basics and Services Command Reference. |
Alarms, errors, and events | - SONET alarms:
- Alarm indication signal—line (AIS-L)
- Alarm indication signal—path (AIS-P)
- Bit error rate signal degrade (BERR-SD)
- Bit error rate signal fail (BERR-SF)
- Bit interleaved parity (BIP) error B1
- Bit interleaved parity (BIP) error B2
- Bit interleaved parity (BIP) error B3
- Loss of frame (LOF)
- Loss of pointer (LOP-P)
- Loss of signal (LOS)
- Far-end bit error: remote error indication—line
(REI-L) (CV-LFE)
- Far-end bit error: remote error indication—path
(REI-P) (CV-PFE)
- Payload mismatch (path label mismatch) (PLM-P)
- Payload unequipped (unequipped STS at path level) (UNEQ-P)
- Remote defect indication—line (RDI-L)
- Remote defect indication—path (RDI-P)
- SDH alarms:
- Multiplex section alarm indication signal (MS-AIS)
- Administrative unit alarm indication signal (AU-AIS)
- Bit error rate signal degrade (BERR-SD)
- Bit error rate signal fail (BERR-SF)
- Bit interleaved parity (BIP) error B1
- Bit interleaved parity (BIP) error B2
- Bit interleaved parity (BIP) error B3
- Loss of frame (LOF)
- Loss of pointer (HP-LOP)
- Loss of signal (LOS)
- Multiplex section remote error indication (MS-REI)
- Higher path label mismatch (HP-PLM)
- Higher path unequipped (HP-UNEQ)
- Multiplex section remote defect indication (MS-RDI)
- Higher path remote defect indication (HP-RDI)
- Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds
(ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE),
far-end unavailable seconds (UAS-LFE, UAS-PFE)
- Severely errored framing (SEF), severely errored framing
seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P),
unavailable seconds (UAS-L, UAS-P)
|