Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 

Network Processing I/O Card SRX1K3K-NP-2XGE-SFPP

 

The Network Processing I/O card (NP-IOC) SRX1K3K-NP-2XGE-SFPP (Figure 1) is an IOC that includes its own Network Processing Unit (NPU), so that traffic traversing the NP-IOC does not have to also traverse the services gateway bus to a remote NPC. This feature makes the NP-IOC well-suited to low-latency applications . It is inserted horizontally into the midplane of the services gateway to communicate with the SFB and to receive power. To use fiber interface media, install enhanced small form-factor pluggable (SFP+) transceivers on the desired ports. LEDs on the faceplate of the NP-IOC indicate port status and connectivity. The SFP+ ports are numbered from left to right, 0-1.

Figure 1: NP-IOC SRX1K3K-NP-2XGE-SFPP
NP-IOC SRX1K3K-NP-2XGE-SFPP

For detailed information about supported transceivers, see the SRX Series Services Gateway Transceiver Guide   at www.juniper.net/documentation/.

Description

  • 2-port Ethernet SFP+ NP-IOC for SRX3400, SRX3600, and SRX1400 Services Gateways

  • Power requirement: 52 W maximum

  • Weight: 2.4 lb (1.1 kg)

  • Maximum configurable MTU: 9192 bytes

Software release

  • Junos OS Release 12.1X44-D10 and later

Cables and connectors

Two SFP+ sockets for Gigabit Ethernet transceivers

Supported SFP+ transceivers:

10GBASE-ER (model number SRX-SFP-10GE-ER)

10GBASE-LR (model number SRX-SFP-10GE-LR)

10GBASE-SR (model number SRX-SFP-10GE-SR)

10GBASE-LRM (model number SFPP-10GE-LRM)

Supported SFP+ direct attach cables:

SRX-SFP-10GE-DAC-1M

SRX-SFP-10GE-DAC-3M

Supported Slots

  • SRX1400: Front slot labeled 2

  • SRX3400: Front slots labeled 1-4 and rear slots labeled 5-7.

  • SRX3600: Front slots labeled 1-6 and rear slots labeled 7-12.

Swapping

NP-IOCs are cold-swap-only. You must power-off the services gateway before removing, replacing, or adding NP-IOCs.

LEDs

SERVICE LED, one bicolor

  • Off–The NP-IOC is administratively disabled.

  • Green–The NP-IOC is available to carry Ethernet traffic.

  • Amber–The NP-IOC is not available to carry Ethernet traffic.

OK/FAIL LED, one bicolor

  • Off–One or more of the following conditions apply:

    • The services gateway is not powered on.

    • The services gateway is still in the process of either booting or shutting down.

    • The services gateway is not configured for chassis clustering.

  • Steady Green–The services gateway is configured for chassis clustering, and the SCM is operating normally.

  • Blinking Green–The NP-IOC is offline. To bring the NP-IOC online, press the ONLINE button.

  • Red–The NP-IOC has failed and is not operating normally.

Serial Number Location

The serial number label for all IOC types is located as shown in Figure 2.

Figure 2: IOC Serial Number Label (SRX3K-16GE-TX Shown, Other IOCs Similar)
IOC Serial Number Label