    LEDs on the faceplate indicate the SPC status (see Table 1).

    Table 1: SPC LEDs

    Label

    Color

    State

    Description

    OK/FAIL

    Green

    On steadily

    SPC is functioning normally.

    Red

    On steadily

    SPC has failed.

    STATUS

    Off

    Off

    SPU is offline. If both SPUs are offline it is safe to remove the SPC from the chassis.

    Green

    On steadily

    SPU is operating normally.

    Amber

    On steadily

    SPU is initializing.

    Red

    On steadily

    SPU has an error or failure.

    SERVICE

    Off

    Off

    Service is not running on the SPU.

    Green

    On steadily

    Service is running on the SPU under acceptable load.

    Amber

    On steadily

    Service on the SPU is overloaded.

    HA

    Green

    On steadily

    Clustering is operating normally. All cluster members and monitored links are available, and no error conditions are detected.

    Red

    On steadily

    A critical alarm is present on clustering. A cluster member is missing or unreachable, or the other node is no longer part of a cluster because it has been disabled by the dual membership and detection recovery process in reaction to a control link or fabric link failure.

    Amber

    On steadily

    All cluster members are present but an error condition has compromised the performance and resiliency of the cluster. The reduced bandwidth could cause packets to get dropped, or result in reduced resiliency as a single point of failure may exist. The error condition may be caused by:

    • The loss of HA links which causes an interface monitoring failure
    • An error in a services processing unit (SPU) or Network Processing Unit (NPU)
    • Failure of the spu-monitoring or cold-sync-monitoring processes
    • A chassis cluster IP monitoring failure

    Unlit

    Off

    The node is not configured for clustering or it has been disabled by the dual membership and detection recovery process in reaction to a control link or fabric link failure.

    LINK/ACT

    Green

    On steadily

    Chassis Cluster Control port link is active.

    Off

    No link.

    ENABLE

    Green

    On steadily

    The Chassis Cluster Control port is enabled.

    Off

    The Chassis Cluster Control port is disabled.

    Two LEDs, located on the craft interface above the SPC, display the status of the SPC and are labeled OK and FAIL.