    JCS1200 Alarm Panel Module Description

    The JCS1200 platform comes with an alarm panel module that provides telecom relays and LED alarm status. You can also connect each Routing Engine to a console by connecting an external breakout cable to the serial port on the alarm panel module.

    JCS1200 Alarm Panel Module Components

    The JCS1200 alarm panel module consists of the following components:

    • Serial connector—This DB-60 connector provides direct access to the serial ports on each of the 12 Routing Engine bays. Use this connector to attach the optional serial port breakout cable and connect up to 12 local consoles.
    • Telco alarm connector—The alarm panel module provides one DB-15 connector (male) for critical, major, and minor telco alarms. Each of the alarms has a relay that enables multiple system alarm indicators to be daisy-chained together.
    • LEDs—The alarm panel module contains seven LEDs. For more information, see JCS1200 Alarm Panel Module LEDs.