Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation  Back up to About Overview 
  
[+] Expand All
[-] Collapse All

Related Documentation

Defining CoS Drop Profiles (J-Web Procedure)

Note: This topic applies only to the J-Web Application package.

J-Web Application package Release 14.1X53-A2 does not support Class of Service (CoS) on EX4600 switches.

You can use the J-Web interface to define CoS drop profiles on EX4500 and EX8200 switches.

To configure CoS drop profiles:

  1. Select Configure > Class of Service > Drop Profile.

    Note: After you make changes to the configuration on this page, you must commit the changes immediately for them to take effect. To commit all changes to the active configuration, select Commit Options > Commit. See Using the Commit Options to Commit Configuration Changes (J-Web Procedure) for details about all commit options.

  2. Select one of the following options:
    • Add—Adds a drop profile. Enter information into the drop profiles page as described in Table 29.
    • Edit—Modifies an existing drop file. Enter information into the drop profiles page as described in Table 29.
    • Delete—Deletes an existing drop profile.

Table 29: Drop Profiles Configuration parameters

Field

Function

Your Action

Drop Profile Name

Specifies the name for a drop profile.

Type the name.

Drop profile graph

Specifies the drop profile graph type

Select one: Segmented or Interpolated.

Drop profile values

Specifies values for the following two parameters of the drop profile: the queue fill level and the drop probability.

The queue fill level represents a percentage of the memory used to store packets in relation to the total amount that has been allocated for that specific queue.

The drop probability is a percentage value that correlates to the likelihood that an individual packet is dropped from the network.

To add new values:

  1. Click Add.
  2. Enter the fill level.
  3. Enter the drop probability.
  4. Click OK.

To edit an existing value, click Edit and modify the fill level and drop probability.

To delete a value, select it and click Delete.

Related Documentation

Release History Table

Release
Description
J-Web Application package Release 14.1X53-A2 does not support Class of Service (CoS) on EX4600 switches.

Modified: 2017-03-05