SRX650 Services Gateway Supported AC Power Cords

Warning: The AC power cord for the services gateway is intended for use with the services gateway only and not for any other use.

Note: In North America, AC power cords must not exceed 4.5 m (approximately 14.75 ft) in length, to comply with National Electrical code (NEC) Section 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical Code (CEC) Section 4-010(3).

Table 32 provides power cord specifications, and Figure 28 depicts the plug on the AC power cord provided for each country or region.

Table 32: AC Power Cord Specifications

Country

Electrical Specification

Plug Standards

Australia

250 VAC, 10 A, 50 Hz

AS/NZ 3112-1993

China

250 VAC, 10 A, 50 Hz

GB2099.1 1996 and GB 1002 1996 (CH1-10P)

Europe (except Italy and United Kingdom)

250 VAC, 10 A, 50 Hz

CEE (7) VII

Italy

250 VAC, 10 A, 50 Hz

CEI 23-16/VII

Japan

125 VAC, 12 A, 50 or 60 Hz

JIS 8303

North America

125 VAC, 10 A, 60 Hz

NEMA 5-15

United Kingdom

250 VAC, 10 A, 50 Hz

BS 1363A

Figure 28: AC Plug Types

AC Plug Types

Note: Power cords and cables must not block access to services gateway components or drape where people might trip on them.