Removing a DC Power Supply Cable from the SRX650 Services Gateway

To remove a power supply cable connected to a DC power supply:

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to an approved site ESD grounding point. For more information about ESD, see Preventing Electrostatic Discharge Damage to the SRX650 Services Gateway.
  2. Switch off the external circuit breakers for all the cables attached to the power supply. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
  3. Remove the power cable from the DC power source.
  4. Attach an ESD grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see Preventing Electrostatic Discharge Damage to the SRX650 Services Gateway.
  5. Make sure the cable is not touching or in the way of any services gateway components and that it does not drape where people could trip on it.
  6. Remove the clear plastic cover protecting the terminal studs on the faceplate.
  7. Attach the power cable to the DC power source.
  8. Verify that the DC source power cabling is correct. If the power cable is correctly installed and the power supply is functioning normally, the POWER LED on the front panel lights green steadily.