Troubleshooting with Chassis and Interface Alarm Messages on the SRX650 Services Gateway
When the services gateway detects an alarm condition, it lights the red or yellow alarm LED on the front panel as appropriate. To view a more detailed description of the alarm cause, issue the show chassis alarms CLI command.
There are two classes of alarm messages:
- Chassis alarms—Indicate a problem with a chassis component such as the cooling system or power supply.
- Interface alarms—Indicate a problem with a specific network interface.
Examples:
regress@jaky# run show chassis alarms
4 alarms currently active
Alarm time Class Description
2009-02-05 09:27:11 PDT Major ge-0/0/5: Link down
2009-02-05 09:27:11 PDT Major ge-0/0/6: Link down
regress@jaky> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online -------------------- CPU less FPC -------------------- 1 Online -------------------- CPU less FPC -------------------- 2 Online -------------------- CPU less FPC -------------------- 3 Online -------------------- CPU less FPC -------------------- 4 Online -------------------- CPU less FPC -------------------- 5 Online -------------------- CPU less FPC -------------------- 6 Online -------------------- CPU less FPC -------------------- 7 Online -------------------- CPU less FPC -------------------- 8 Online -------------------- CPU less FPC --------------------
For more information about the show chassis alarms command,
see the Junos OS Monitoring and Troubleshooting Guide for Security Devices .
Table 26 describes alarms that can occur for a services gateway chassis component.
Table 26: Alarms for Services Gateway Chassis Components
Component | Alarm Conditions | Action | Alarm Severity |
---|---|---|---|
Boot media | The services gateway boots from an alternate boot device. | If the internal flash fails at startup, the services gateway automatically boots itself from the alternative boot device (USB storage device). If you configured your services gateway to boot from an alternative boot device, ignore this alarm condition. If you did not configure the services gateway to boot from an alternative boot device, contact JTAC. | Yellow (minor) |
Gigabit-Backplane Physical Interface Module (GPIM) | A GPIM has failed. | Contact JTAC. | Red (major) |
Hardware components on services gateway | The services gateway chassis temperature is too warm. |
| Yellow (minor) |
The services gateway fan has failed. | Place your hand near the exhaust vents at the rear of the chassis to determine whether the fan is pushing air out of the chassis. Replace the failed fan and contact JTAC. | Red (major) |
![]() | Note:
For more information about alarms, see the Junos OS Monitoring and Troubleshooting Guide for Security Devices |
Related Documentation
- Troubleshooting with the CLI on the SRX650 Services Gateway
- SRX650 Services Gateway Front Panel
- SRX650 Services Gateway Back Panel
- Troubleshooting the Power System on the SRX650 Services Gateway
- Using the RESET CONFIG Button on the SRX650 Services Gateway
- Changing the RESET CONFIG Button Behavior on the SRX650 Services Gateway