SRX5800 Services Gateway High-Capacity AC Power Supply LEDs

Each high-capacity AC power supply faceplate contains four LEDs that indicate the status of the power supply (see Table 22). The power supply status is also reflected in two LEDs on the craft interface. In addition, a power supply failure triggers the red alarm LED on the craft interface.

Table 22: High-Capacity AC Power Supply LEDs

Label

Color

State

Description

AC-1 OK

Green

Off

AC power applied to power supply at the upper appliance inlet is not within the normal operating range.

On

AC power applied to power supply at the upper appliance inlet is within the normal operating range.

AC-2 OK

Green

Off

AC power applied to power supply at the lower appliance inlet is not within the normal operating range.

On

AC power applied to power supply at the lower appliance inlet is within the normal operating range.

DC OK

Green

Off

DC power outputs generated by the power supply are not within the normal operating ranges.

On

DC power outputs generated by the power supply are within the normal operating ranges.

PS FAIL

Red

Off

Power supply is functioning normally.

On

Power supply is not functioning normally. Check the AC-1 OK, AC-2 OK, and DC OK LEDs for more information.