Maintaining Port Modules on the SRX5800 Services Gateway
Purpose
For optimum services gateway performance, verify the condition of the port modules installed in Flex IOCs.
Action
On a regular basis:
- Check the LEDs on port modules faceplates. The meaning of the LED states differs for various port modules. If the Flex IOC that houses the port modules detects a port modules failure, the Flex IOC generates an alarm message to be sent to the Routing Engine.
- Issue the CLI show chassis fpc pic-status command. The port modules slots in an FPC are numbered from 0 through 1, top to bottom:
user@host> show chassis fpc pic-status
Slot 0 Online SRX5k SPC PIC 0 Online SPU Cp-Flow PIC 1 Online SPU Flow Slot 3 Online SRX5k DPC 4X 10GE PIC 0 Online 1x 10GE(LAN/WAN) RichQ PIC 1 Online 1x 10GE(LAN/WAN) RichQ PIC 2 Online 1x 10GE(LAN/WAN) RichQ PIC 3 Online 1x 10GE(LAN/WAN) RichQ Slot 5 Online SRX5k FIOC PIC 0 Online 16x 1GE TX PIC 1 Online 4x 10GE XFP
For further description of the output from the command, see the Junos OS System Basics and Services Command Reference.
Related Documentation
- Routine Maintenance Procedures for the SRX5800 Services Gateway
- Maintaining the Air Filter on the SRX5800 Services Gateway
- Maintaining the Fan Trays on the SRX5800 Services Gateway
- Maintaining the SRX5800 Services Gateway Host Subsystem and SCBs
- Maintaining SPCs, IOCs, and Flex IOCs on the SRX5800 Services Gateway
- Maintaining SRX5800 Services Gateway Network Cables
- Maintaining SRX5800 Services Gateway Power Supplies