SRX5800 Services Gateway Cooling System Description

The cooling system consists of the following components:

The cooling system components work together to keep all services gateway components within the acceptable temperature range (see Figure 17, Figure 18, Figure 20, and Figure 21). The services gateway has two fan trays located in the front of the device that install horizontally above and below the card cage. The fan trays are interchangeable and are hot-insertable and hot-removable.

Figure 17: Airflow Through the Chassis

Image g004021.gif

The host subsystem monitors the temperature of the device components. When the device is operating normally, the fans function at lower than full speed. If a fan fails or the ambient temperature rises above a threshold, the speed of the remaining fans is automatically adjusted to keep the temperature within the acceptable range. If the ambient maximum temperature specification is exceeded and the system cannot be adequately cooled, the Routing Engine shuts down the system by disabling output power from each PEM.

There is a single air intake in the front of the services gateway. Air is pushed up through an air filter, through the card cage, and then through the upper fan tray where it combines in a common exhaust plenum and is exhausted out the upper rear of the system.

Two different types of fan tray are available:

Figure 18: Standard-Capacity Fan Tray (Same Upper and Lower)

Image g004022.gif

Figure 19: High-Capacity Fan Tray (Same Upper and Lower)

Image g030294.gif

Figure 20: Air Filter

Image g004072.gif

Figure 21: Standard-Capacity Air Filter Tray

Image g004071.gif

Figure 22: High-Capacity Air Filter Tray

Image g030295.gif