SRX5800 Services Gateway Services Processing Card LEDs

LEDs on the faceplate indicate the SPC status (see Table 11).

Table 11: SPC LEDs

Label

Color

State

Description

OK/FAIL

Green

On steadily

SPC is functioning normally.

Red

On steadily

SPC has failed.

STATUS

Off

Off

SPU is offline. If both SPUs are offline it is safe to remove the SPC from the chassis.

Green

On steadily

SPU is operating normally.

Amber

On steadily

SPU is initializing.

Red

On steadily

SPU has an error or failure.

SERVICE

Off

Off

Service is not running on the SPU.

Green

On steadily

Service is running on the SPU under acceptable load.

Amber

On steadily

Service on the SPU is overloaded.

HA

Green

On steadily

All cluster members and monitored links are available.

Red

On steadily

A cluster member is missing or unreachable, or the other node is no longer part of a cluster because it has been disabled by the dual membership and detection recovery process in reaction to a control link or fabric link failure.

Amber

On steadily

All cluster members are present, but one or more monitored links are down.

Unlit

Off

The node is not configured for clustering or it has been disabled by the dual membership and detection recovery process in reaction to a control link or fabric link failure.

LINK/ACT

Green

On steadily

Chassis Cluster Control port link is active.

Off

No link.

ENABLE

Green

On steadily

The Chassis Cluster Control port is enabled.

Off

The Chassis Cluster Control port is disabled.

Two LEDs, located on the craft interface above the SPC, display the status of the SPC and are labeled OK and FAIL.

Related Documentation