Index

Symbols  A  B  C  D  E  F  G  H  I  J  L  M  N  O  P  Q  R  S  T  U  W  X

 

Symbols

#, comments in configuration statements
( ), in syntax descriptions
< >, in syntax descriptions
[ ], in configuration statements
{ }, in configuration statements
| (pipe), in syntax descriptions
 

A

AC plug types
AC power cables    
specifications
AC power supply    
cord     See AC power cord    
description
electrical specifications
high-capacity    
description
electrical specifications
installing
removing    12
upgrading
AC power supply cord    
connecting
disconnecting
specifications
AC specifications    
circuit breaker
electrical
accessory box    
parts list
removing
accident procedures, electrical
agency approvals
air filter    
installing
maintaining
removing
routine inspection of
airflow    
required clearance around chassis for
alarms    
cutoff/lamp test button
LEDs (red and yellow) on craft interface
messages, list of
relay contacts    
connecting wire
disconnecting wire
wire specifications
temperature, displaying
altitude, acceptable range
antistatic mat, using
attenuation in fiber-optic cable
AUX port     See auxiliary port on Routing Engine    
auxiliary port (for Routing Engine management)    
cable    
connection during initial installation
connector pinouts (DB-9)
replacement instructions
specifications    12
auxiliary port on Routing Engine    
description
 

B

battery-handling warning
booting the services gateway    12
braces, in configuration statements
brackets    
angle, in syntax descriptions
square, in configuration statements
 

C

cable    
auxiliary or console port (for Routing Engine management)    
connecting during initial installation
replacing
cover    
installation
DPC    
connecting during maintenance    12
Ethernet port (for Routing Engine management)    
connecting during initial installation
replacing
fiber-optic    
attenuation
cleaning instructions for transceivers
dispersion
multimode and single-mode
transmission distance, maximum
wavelength ranges
grounding     See DC power and grounding cables    
IOC    
disconnecting
maintaining
port module    
disconnecting
power     See AC power cord    
cable management system    
description
fiber-optic cable, use with
cable manager    
installing
reinstalling    
after chassis installation
removing    
before chassis installation
chassis    
alarm messages     See alarm, messages    
dimensions
ESD points
grounding points    12
installing in rack
weight
checklist for site preparation
chromatic dispersion in fiber-optic cable
class 1 laser warning
class 1 LED warning
cleaning instructions    
fiber-optic transceivers
clearance, around rack
CLI    
as troubleshooting tool
command    
to display chassis alarm messages
to display IOC status    12
to display port module status
to display serial number
cold-swap-only components, description
commands    
ping
show chassis alarms
show chassis fpc    
for IOC status    12
show chassis fpc pic-status
show chassis hardware
show chassis IOC pic-status
traceroute
comments, in configuration statements
compatibility, electromagnetic
compliance statements for EMC requirements    
Canada
European Community
Japan
United States
components    
cable management system
chassis
cooling system
craft interface
field replacement
Flex IOC
host subsystem
IOC
midplane
port module
power supplies
redundancy
Routing Engine
SCB
SPC
components, packing for shipment
connecting    
AC power supply cord
DC power supply cable
CONSOLE port     See console port on Routing Engine    
console port (for Routing Engine management)    
cable    
connection during initial installation
connector pinout (RJ-45)    12
replacement instructions
specifications    12
console port on Routing Engine    
description
conventions    
notice icons
text and syntax
cooling system    
description
troubleshooting
craft interface    
alarm cutoff/lamp test button
alarm relay contacts
description
host subsystem LEDs
installing
IOC and SPC LEDs
LEDs    
alarm (red and yellow)
online buttons
power supply LEDs
removing
routine inspection of
curly braces, in configuration statements
customer support, contacting
 

D

DC power    
source cabling
DC power circuit breaker
DC power supply    
cables     See DC power supply cable, specifications    
description
electrical specifications
installing
removing    12
DC power supply cable    
connecting
disconnecting
lugs
specifications
DC specifications    
electrical    12
disconnecting    
AC power supply cord
DC power supply cable
dispersion in fiber-optic cable
DPC    
cable    
installation instructions
 

E

earthquakes    
tested toleration for seismic
EIA rack standards
electrical    
accident procedures
safety guidelines and warnings
electrical specifications    1234
electricity    
site wiring guidelines
electromagnetic    
compatibility     See EMC    
pulse
electrostatic    
bag, using to store components
EMC (EMI)    
suppression
EMC requirements    
Canada
European Community
Japan
United States
EMP
environmental specifications
ESD    
preventing damage to components by
Ethernet port (for Routing Engine management)    
cable    
connection during initial installation
replacement instructions
specifications
Ethernet port on Routing Engine    
description
ETSI rack standards
 

F

fan tray    
installing
maintaining
reinstalling    
after chassis installation
removing    
before chassis installation
troubleshooting
fan trays    
description
field-replaceable units    
listed
fire safety requirements
Flex I/O Card     See Flex IOC    
Flex IOC    
removing
font conventions
 

G

grounding (electrical) specifications    
AC-powered services gateway
DC-powered services gateway
grounding cables    
lug
guidelines, electrical safety
 

H

hardware components    
power requirements    12
higher-order mode loss (HOL)
host subsystem    
description
LEDs
hot-pluggable components, description
hot-removable and hot-insertable components, description
humidity (relative), acceptable
 

I

I/O Card     See IOC    
installation    
AC power, connecting
instructions warning
parts received, verifying
unpacking the services gateway
installation instructions    
alarm relay contact wires    
tools required
cable, auxiliary or console port (for Routing Engine management)    
for maintenance or replacement
tools required
cable, DPC    
for maintenance or replacement
cable, Ethernet port (for Routing Engine management)    
for maintenance or replacement
tools required
cable, PIC    
for maintenance or replacement
DC power and grounding cables    
tools required
installing    
AC power supply
air filter
alarm relay contact wires    
during initial installation
for maintenance or replacement    12
cable manager
cable, auxiliary or console port (for Routing Engine management)    
during initial installation
cable, Ethernet port (for Routing Engine management)    
during initial installation
craft interface
DC power supply
DC power, connecting
fan tray
IOC
IOC, connecting
PIC, connecting
power and grounding cables    
tools required
Installing    
SPC
instructions    
calculation    
power requirements
cleaning     See cleaning instructions    
maintenance    
IOC
port module
interference    
electromagnetic
radio frequency
IOC    
cable    
removal instructions
connecting
holding
installing
LEDs
maintaining
maintenance
removing
status, checking    123
storing
IOCs    
components
troubleshooting
 

J

jewelry removal warning
JTAC
Juniper Networks Technical Assistance Center (JTAC)
Juniper Technical Assistance Center     See JTAC    
 

L

laser beam warning
laser safety guidelines
LEDs    
AC power supplies
alarm (red and yellow on craft interface)    
description
DC power supplies
host subsystem
IOC
on components
on craft interface
power supplies
SCB
lightning activity warning
link loss, calculating
lugs for DC power and grounding cables
lugs for DC power cables
 

M

maintaining    
air filter
fan tray
IOC    12
maintenance guidelines    
IOC    12
IOC cable
port module
management    
port     See Ethernet port on Routing Engine    
midplane    
description
functions
modal dispersion in fiber-optic cable
mode loss, higher-order
multimode fiber-optic cable     See cable, fiber-optic    
 

N

notice icons
 

O

online buttons    
craft interface
operating temperature warning
overview    
services gateway
 

P

packing services gateway    
components for shipment
parentheses, in syntax descriptions
PEMs     See power supplies    
physical specifications
PIC    
cable    
installation instructions
connecting
SONET/SDH    
power budget calculation
ping command
pinouts    
RJ-45 cable connector ports (auxiliary/console)
RJ-45 Ethernet cable connector port
plug types    
AC
port    
auxiliary on Routing Engine     See auxiliary port on Routing Engine    
console on Routing Engine     See console port on Routing Engine    
Ethernet on Routing Engine     See Ethernet port on Routing Engine    
port module    
components
maintenance
status, checking
Port module    
cable    
removal instructions
troubleshooting
power    
budget calculation
cables and cords     See AC power cord; DC power cables    
margin calculation
requirements for hardware components    12
surges
power supplies    
AC electrical specifications
cables     See DC power    
DC electrical specifications
description
LEDs    123
power supply    
reinstalling    
after chassis installation
removing    
before chassis installation
power system    
AC electrical specifications
DC electrical specifications
troubleshooting
powering off the services gateway
powering on the services gateway    12
product disposal warning
 

Q

qualified personnel warning
 

R

rack    
clearance around, required
mounting bracket hole spacing
size and strength required
standards, EIA and ETSI
rack mounting    
shelves
rack requirements    
mounting
radiation from open port apertures warning
radio frequency interference, preventing
redundancy
reinstalling    
cable manager    
after chassis installation
fan tray    
after chassis installation
power supply    
after chassis installation
SCB    
after chassis installation
relative humidity, acceptable
removal instructions    
cable    
auxiliary or console port (for Routing Engine management)
Ethernet port (for Routing Engine management)    12
IOC
port module
removing    
AC power supply    12
air filter
alarm relay contact wires
cable manager    
before chassis installation
craft interface
DC power supply    12
fan tray    
before chassis installation
IOC
power supply    
before chassis installation
SCB    
before chassis installation
SFP
XFP
Removing    
SPC
repair policies
restricted access area warning
return materials authorization
return procedure
RFI
RJ-45 cable connector pinouts
RJ-45 cable connector pinouts (auxiliary and console ports)
RMA     See return materials authorization    
Routing Engine    
boot sequence
components
description
for dual chassis cluster control link
management ports    
cable and wire specifications
ports
status indicator lights
USB port
 

S

safety guidelines, laser
safety requirements    
fire
fire suppression equipment
SCB    
reinstalling    
after chassis installation
removing    
before chassis installation
SCBs    
components
description
LEDs
seismic (earthquake)
serial number    
in output from show chassis hardware command
services gateway    
parts list
physical specifications
returning
unpacking
weight
Services Processing Card     See SPC    
Services Processing Unit     See SPU    
SFP    
description
installing
removing
shipment    
packing the components
shipping container    
unpacking
weight
show chassis alarms command    123
show chassis fpc command    
for IOC status
show chassis fpc pic-status command    12
show chassis hardware command
show chassis IOC command
show chassis IOC detail command
show chassis SPC command
show chassis SPC detail command
signal dispersion
signaling, distance limitations
single-mode fiber-optic cable     See cable, fiber-optic    
site    
electrical wiring specifications
environmental specifications
preparation    
checklist
routine inspection
SPC    
installing
removing
status, checking
SPCs    
troubleshooting
specifications    
AC power cord
cable    
power
Routing Engine management ports    12
clearance around rack
DC power supply cable
electrical    
cable and wiring
environmental
power    
drawn by hardware components    12
power system    12
rack    
front-mount flange hole spacing
mounting bracket hole spacing
size and strength
thermal output
wires to external alarm-reporting devices
SPU
startup, system    
monitoring    12
support, requesting from JTAC    12
surge protection
Switch Control Boards     See SCBs    
syntax conventions
 

T

temperature, acceptable range
thermal output
tolerances    
environmental
tools required    
chassis    
returning for repair or replacement
hardware components    
returning for repair or replacement
maintaining
replacement
traceroute command
transmission distances, fiber-optic cable
troubleshooting    
CLI commands
cooling system
fans    12
IOC
port module
power system
SPC
 

U

U (rack unit)
unpacking the services gateway
 

W

warning    
battery-handling
class 1 laser
class 1 LED
electrical safety guidelines
installation instructions
jewelry removal
laser beam
lightning activity
operating temperature
product disposal
rack-mount requirements
radiation from open apertures
wavelength ranges supported by fiber-optic cable
wiring, electrical     See electricity    
 

X

XFP    
description
installing
removing