Maintaining the Fan Tray on the SRX5600 Services Gateway
Purpose
For optimum cooling, verify the condition of the fans.
Action
- Monitor the status of the fans. A fan tray contains multiple fans that work in unison to cool the services gateway components. If one fan fails, the host subsystem adjusts the speed of the remaining fans to maintain proper cooling. A red alarm is triggered when a fan fails, and a yellow alarm and red alarm is triggered when a fan tray is removed.
- To display the status of the cooling system, issue the show chassis environment command. The output is similar to the
following:
user@host> show chassis environment
Class Item Status Measurement Temp PEM 0 OK 35 degrees C / 95 degrees F PEM 1 OK 35 degrees C / 95 degrees F PEM 2 Absent PEM 3 Absent Routing Engine 0 OK 37 degrees C / 98 degrees F Routing Engine 1 Absent CB 0 Intake OK 30 degrees C / 86 degrees F CB 0 Exhaust A OK 32 degrees C / 89 degrees F CB 0 Exhaust B OK 33 degrees C / 91 degrees F CB 0 ACBC OK 30 degrees C / 86 degrees F CB 0 SF A OK 42 degrees C / 107 degrees CB 0 SF B OK 34 degrees C / 93 degrees F CB 1 Intake Absent CB 1 Exhaust A Absent CB 1 Exhaust B Absent CB 1 ACBC Absent CB 1 SF A Absent CB 1 SF B Absent FPC 0 Intake OK 36 degrees C / 96 degrees F FPC 0 Exhaust A OK 32 degrees C / 89 degrees F FPC 0 Exhaust B OK 39 degrees C / 102 degrees FPC 0 pfe0/I3 TSensor OK 35 degrees C / 95 degrees F FPC 0 pfe0/I3 Chip OK 41 degrees C / 105 degrees FPC 0 pfe1/I3 TSensor OK 35 degrees C / 95 degrees F FPC 0 pfe1/I3 Chip OK 39 degrees C / 102 degrees FPC 0 pfe0/XLR TSensor OK 38 degrees C / 100 degrees FPC 0 pfe0/XLR Chip OK 52 degrees C / 125 degrees FPC 0 pfe1/XLR TSensor OK 30 degrees C / 86 degrees F FPC 0 pfe1/XLR Chip OK 51 degrees C / 123 degrees FPC 0 IA TSensor OK 39 degrees C / 102 degrees FPC 0 IA Chip OK 43 degrees C / 109 degrees FPC 0 Forbes 0 TSensor OK 29 degrees C / 84 degrees F FPC 0 Forbes 0 Chip OK 48 degrees C / 118 degrees FPC 0 Forbes 1 TSensor OK 32 degrees C / 89 degrees F FPC 0 Forbes 1 Chip OK 45 degrees C / 113 degrees FPC 2 Intake OK 29 degrees C / 84 degrees F FPC 2 Exhaust A OK 37 degrees C / 98 degrees F FPC 2 Exhaust B OK 44 degrees C / 111 degrees FPC 2 I3 0 TSensor OK 45 degrees C / 113 degrees FPC 2 I3 0 Chip OK 50 degrees C / 122 degrees FPC 2 I3 1 TSensor OK 43 degrees C / 109 degrees FPC 2 I3 1 Chip OK 46 degrees C / 114 degrees FPC 2 I3 2 TSensor OK 40 degrees C / 104 degrees FPC 2 I3 2 Chip OK 46 degrees C / 114 degrees FPC 2 I3 3 TSensor OK 35 degrees C / 95 degrees F FPC 2 I3 3 Chip OK 39 degrees C / 102 degrees FPC 2 IA 0 TSensor OK 48 degrees C / 118 degrees FPC 2 IA 0 Chip OK 46 degrees C / 114 degrees FPC 2 IA 1 TSensor OK 41 degrees C / 105 degrees FPC 2 IA 1 Chip OK 45 degrees C / 113 degrees Fans Top Rear Fan OK Spinning at normal speed Bottom Rear Fan OK Spinning at normal speed Top Middle Fan OK Spinning at normal speed Bottom Middle Fan OK Spinning at normal speed Top Front Fan OK Spinning at normal speed Bottom Front Fan OK Spinning at normal speed
![]() | Note: The fan numbers are stamped into the fan tray sheet metal next to each fan. |
Related Documentation
- Routine Maintenance Procedures for the SRX5600 Services Gateway
- Maintaining the Air Filter on the SRX5600 Services Gateway
- Maintaining the SRX5600 Services Gateway Host Subsystem and SCBs
- Maintaining SPCs, IOCs, and Flex IOCs on the SRX5600 Services Gateway
- Maintaining Port Modules on the SRX5600 Services Gateway
- Maintaining SRX5600 Services Gateway Network Cables
- Maintaining SRX5600 Services Gateway Power Supplies