SRX5600 Services Gateway I/O Card LEDs

LEDs on the 4-port 10-Gigabit Ethernet faceplate indicate the port status. LEDs are labeled top to bottom 0/0 through 0/3 (see Table 5).

Table 5: 4-Port 10-Gigabit Ethernet IOC LEDs

Label

Color

State

Description

OK/FAIL

Green

On steadily

IOC is functioning normally.

Red

On steadily

IOC has failed.

TUNNEL

Green

Off

Normal operating mode.

On steadily

Port configured in tunnel mode.

LINK

Green

On steadily

Link is active.

Off

No link.

LEDs on the 40–port Gigabit Ethernet faceplate indicate the port status. LEDs are labeled horizontally and top to bottom 0/0 through 0/5, 1/0 through 1/5, 2/0 through 2/5, and 3/0 through 3/5 (see Table 6).

Table 6: 40-Port Gigabit Ethernet IOC LEDs

Label

Color

State

Description

OK/FAIL

Green

On steadily

IOC is functioning normally.

Red

On steadily

IOC has failed.

LINK

Green

On steadily

Link is active.

Off

No link.

Related Documentation