Replacing the Switch Fabric Board on the SRX3600 Services Gateway

The SFB is accessible from the front panel, in the topmost slot. It weighs approximately 5.1 lb (2.3 kg). Before you replace the SFB, you must power off the services gateway.

To replace an SFB:

  1. Attach an ESD grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see Preventing Electrostatic Discharge Damage to the SRX3600 Services Gateway.
  2. If you have not already done so, power off the services gateway by pressing the Power button on the front panel of the Switch Fabric Board (SFB) for three to five seconds.

    The PWR LED blinks to show you that the services gateway is shutting down. Wait for the services gateway to shut down before proceeding.

  3. Place an electrostatic bag or antistatic mat on a flat, stable surface.
  4. Disconnect any cables attached to the SFB front panel connectors.
  5. Loosen the screws on either end of the SFB front panel.
  6. Pull open the ejector handles and slide the SFB halfway out of the chassis.
  7. Place one hand underneath the SFB to support it and slide it completely out of the chassis.
  8. Place the SFB on the antistatic mat.

    Figure 52: Removing the SFB

    Image g036061.gif
  9. Carefully align the sides of the replacement SFB with the guides inside the chassis.
  10. Slide the SFB into the chassis until you feel resistance.
  11. Grasp both ejector handles and press toward the center of the card to fully seat the SFB.
  12. Tighten the screws on either side of the card.
  13. Reconnect the cables, if any, that you disconnected from the SFB front panel connectors in Step 4.

    Figure 53: Inserting the SFB

    Image g036060.gif
  14. Power on the services gateway by pressing the Power button on the front panel of the SFB for three to five seconds. Wait for the services gateway to start.
  15. Verify that the SFB is functioning normally by checking the LEDs on its faceplate. The SFB STATUS LED should light steadily green a few minutes after the services gateway is powered on. If the SFB STATUS LED is red, remove and install the SFB again. If the SFB STATUS LED still lights steadily red, the SFB is not functioning properly. Contact your customer support representative.

    To check the status of the SFB:


    user@host> show chassis environment fpc 0
    CB 0 status:
      State                      Online Master
      Temperature                30 degrees C / 86 degrees F
      Power 1
        1.2 V                     1202 mV
        1.5 V                     1511 mV
        1.8 V                     1798 mV
        2.5 V                     2481 mV
        3.3 V                     3306 mV
        5.0 V                     4956 mV
        12.0 V                   12084 mV
        1.25 V                    1250 mV
        3.3 V SM3                 3287 mV
        5.0 V RE                  5046 mV
        12.0 V RE                11910 mV
      Power 2
        11.3 V bias PEM          11292 mV
        11.3 V bias FPD          11156 mV
        11.3 V bias POE 0        11253 mV
        11.3 V bias POE 1        11272 mV
      Bus Revision               42
      FPGA Revision              1
    