Maintaining the Power Supplies on the SRX3400 Services Gateway
To maintain the power supplies, follow these guidelines:
- To check the status of the power supplies, issue the show chassis environment pem command. The output is
similar to the following:
user@host> show chassis environment pem
PEM 0 status: State Online PEM 1 status: State Online
- Make sure that the power and grounding cables are arranged so that they do not obstruct access to other services gateway components.
- Routinely check the PWR status LED on the SFB faceplate. If this LED is solid green, the power supplies are functioning normally.
- Periodically inspect the site to ensure that the grounding and power cables connected to the services gateway are securely in place and that there is no moisture accumulating near the services gateway.
Related Documentation
- Required Tools and Parts for Maintaining the SRX3400 Services Gateway Hardware Components
- Routine Maintenance Procedures for the SRX3400 Services Gateway
- Grounding the SRX3400 Services Gateway
- Maintaining the Air Filter on the SRX3400 Services Gateway
- Maintaining the Fan Tray on the SRX3400 Services Gateway
- Maintaining the Routing Engine on the SRX3400 Services Gateway