The SFB is accessible from the front panel, in the topmost slot. It weighs approximately 5.1 lb (2.3 kg). Before you replace the SFB, you must power off the Services Gateway.
To replace an SFB:
The PWR LED blinks to show you that the device is shutting down. Wait for the device to shut down before proceeding.
Figure 48: Removing the SFB
Figure 49: Inserting the SFB
To check the status of the SFB:
user@host> show chassis environment
fpc 0
CB 0 status: State Online Master Temperature 30 degrees C / 86 degrees F Power 1 1.2 V 1202 mV 1.5 V 1511 mV 1.8 V 1798 mV 2.5 V 2481 mV 3.3 V 3306 mV 5.0 V 4956 mV 12.0 V 12084 mV 1.25 V 1250 mV 3.3 V SM3 3287 mV 5.0 V RE 5046 mV 12.0 V RE 11910 mV Power 2 11.3 V bias PEM 11292 mV 11.3 V bias FPD 11156 mV 11.3 V bias POE 0 11253 mV 11.3 V bias POE 1 11272 mV Bus Revision 42 FPGA Revision 1