[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

Removing Components from the Chassis for Manual Lifting of the SRX3400 Services Gateway

To make the Services Gateway light enough to install manually, you first remove most components from the chassis as shown in Figure 27 and Figure 28 The procedure in this section for removing components from the chassis is for initial installation only, and assumes that you have not connected power cables to the Services Gateway:

Figure 27: Components to Remove from the Front of the Device

Image g030265.gif

Figure 28: Components to Remove from the Rear of the Device

Image g030266.gif

To remove the components from the device:

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see Preventing Electrostatic Discharge Damage to the SRX3400 Services Gateway.
  2. If you have not already done so, power off the device by pressing the Power button on the front panel of the Switch Fabric Board (SFB) for three to five seconds. The PWR LED blinks to show you that the device is shutting down. Wait for the device to shut down before proceeding.
  3. Release each component by loosening its retaining screws and unlatching its ejector handles as appropriate.
  4. Slide each component out of the chassis evenly so that it does not become stuck or damaged.
  5. Label each component as you remove it so you can reinstall it in the correct location.
  6. Immediately store each removed component in an electrostatic bag.
  7. Do not stack removed components. Lay each one on a flat surface.

Related Topics


[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]