[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

Connecting the SRX3400 Services Gateway to an AC Power Supply

Caution: Do not mix AC and DC power supplies within the same Services Gateway. Damage to the device might occur.

You connect AC power to the device by attaching power cords from the AC power sources to the AC appliance inlets located on the power supplies. The power cords are provided.

To connect the AC power cords to the device for each power supply:

  1. Locate the power cord or cords you will use to connect the device to AC power. The device is not shipped with AC power cords. You must order them separately using the model number shown in Table 37.
  2. Insert the appliance coupler end of the power cord into the appliance inlet on the power supply as shown in Figure 40.

    Figure 40: Connecting to AC Power

    Image g036009.gif

  3. Snap the wire bail on the power supply over the power cord to prevent the power cord from accidentally disengaging.
  4. Insert the power cord plug into an external AC power source receptacle.

    Note: Each power supply must be connected to a dedicated AC power feed and a dedicated external circuit breaker. We recommend that you use a 15 A (250 VAC) minimum, or as permitted by local code.

  5. Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and access to device components or drape where people could trip on it.
  6. Repeat steps 1 through 5 for the remaining power supplies.

Note: If power is lost to the Services Gateway, the Power-On/Power-Off state is retained. For example, if the Services Gateway loses power while the device is On, when power returns, the device will still be in the On state.

Related Topics


[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]