The LEDs on the SRX240 Services Gateway enable you to determine the performance and operation. The Power LED, located on the front panel of the services gateway, indicates the different settings with respect to the power system.

Table 34 describes different Power LED status indications and the required corrective actions.

Table 34: Services Gateway Power LED Status

LED Status

Meaning

Possible Cause and Corrective Action

Green

The services gateway is receiving power, and the internal power supply is functional.

Normal indication. No action is required.

Yellow

The Power button has been pressed and quickly released. The services gateway is shutting down or starting up.

Normal indication. No action is required.

Off

The services gateway is not receiving power.

  • Verify that the AC power cord from the power source to the services gateway is not damaged. If the insulation is cracked or broken, immediately replace the cord or cable.
  • Ensure that the socket you plug in is in working condition.
  • Ensure that the an AC input voltage is between 110 and 240 VAC.
  • If you cannot determine the cause of the problem or need additional assistance, contact the Juniper Networks Technical Assistance Center (JTAC).

    See Juniper Networks Technical Assistance Center.

Monitoring the SRX240 Services Gateway DC Power System

The back panel of an SRX240 Services Gateway with DC power supply model has two LEDs that indicate the status of the dual feed for the integrated DC power supply.

Table 35 describes the LEDs on the DC power feeds on the SRX240 Services Gateway with DC power supply model.

Table 35: SRX240 Services Gateway DC Power Feed LEDs

DC Input

DC Output

LED A

LED B

Input A

Input B

Input is normal.

Input is normal.

No output1.

Red

Red

Output is normal.

Green

Green

Input is connected but has failed because the power supply fuse has failed or input voltage is low.

Input is normal.

Output is normal.

Red (blinking)

Green

Input is normal.

Input is connected but has failed because the power supply fuse has failed or the input voltage is low.

Output is normal.

Green

Red (blinking)

Input breaker open or no DC input connected.

Input is normal.

Output is normal.

Red (blinking)

Green

Input has failed.

Input has failed.

No output.

Red (blinking)

Red (blinking)

No input.

No input.

No output.

Off

Off

(1) No output because of an output side failure or an open connection.