Packing the SRX220 Services Gateway and Components for Shipment

This topic includes the following sections:

Packing the Services Gateway

To pack the services gateway for shipment:

  1. Retrieve the shipping box and packing materials in which the device was originally shipped. If you do not have these materials, contact your Juniper Networks representative about approved packaging materials.
  2. Attach an ESD grounding strap to your bare wrist and connect the strap to the ESD point on the chassis or to an outside ESD point if the device is disconnected from earth ground.
  3. On the console or other management device connected to the services gateway, enter command-line interface (CLI) operational mode and issue the following command to shut down the services gateway software:

    admin@host> request system power-off

    Wait until a message appears on the console confirming that the operating system has halted.

  4. Shut down power to the device by pressing the Power button on the front panel of the device.
  5. Disconnect power from the device.
  6. Remove the cables that connect to all external devices.
  7. Remove all field-replaceable FRUs from the device.
  8. If the device is installed on a wall or rack, have one person support the weight of the device while another person unscrews and removes the mounting screws.
  9. Place the device in the shipping box.
  10. Cover the device with an ESD bag, and place the packing foam on top of and around the device.
  11. Replace the accessory box on top of the packing foam.
  12. Securely tape the box closed.
  13. Write the Return Materials Authorization (RMA) number on the exterior of the box to ensure proper tracking.

Packing the Components for Shipment

Follow these guidelines for packing and shipping individual components of the services gateway:

Caution: Do not stack any of the services gateway components during packing.