Troubleshooting the Network and Services Processing Card on the SRX1400 Services Gateway
To troubleshoot the Network and Services Processing Card (NSPC), follow these guidelines:
- Make sure the NSPC is properly seated in the slot and its screws are tightened.
- Use the CLI show chassis fpc 1 command to
check the status of installed NSPC. As shown in the sample output
for show chassis fpc 1, the value Online in
the column labeled State indicates that the NSPC is functioning
normally:
user@host> show chassis fpc 1
Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 1 Online 34 40 0 1024 3 27
Note: Because the NSPC occupies slot 1 and slot 3 of the SRX1400 Services Gateway chassis, you can use the show chassis fpc 1 and show chassis fpc 3 commands to check the status of NSPC.
- Use the CLI show chassis fpc 1 detail command
for more detailed output.
user@host> show chassis fpc 1 detail
Slot 1 information: State Online Temperature 34 degrees C / 93 degrees F Total CPU DRAM 1024 MB Total RLDRAM 0 MB Total DDR DRAM 0 MB Start time: 2010-07-08 13:56:24 UTC Uptime: 5 days, 20 hours, 22 minutes, 7 seconds Max Power Consumption 0 Watts
For further descriptions of the output from the commands, see the Junos System Basics and Services Command Reference.