Installing a DC Power Supply in the SRX1400 Services Gateway

To install a DC power supply:

  1. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
  2. Attach an ESD grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see Preventing Electrostatic Discharge Damage to the SRX1400 Services Gateway.
  3. Orient the power supply so that the locking lever is on the left, as shown in Figure 27.

    Figure 27: Installing a DC Power Supply in the SRX1400 Services Gateway

    Image g033548.gif
  4. Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot. The power supply faceplate should be flush with any adjacent power supply faceplate.
  5. Proceed with connecting the power supply to DC power. See Connecting the SRX1400 Services Gateway to a DC Power Supply.