Description
|
- Two OC3 or STM1 ports
- SONET or SDH is configurable on a per-port granularity
- SONET channelization:
- 2 OC3 channels
- 6 DS3 channels
- 168 DS1 channels
- 1011 DS0 channels
- SDH channelization:
- 2 STM1 channels (non-concatenated)
- 6 E3 channels
- 126 E1 channels
- 1011 DS0 channels
- Power requirement: 0.56 A @ 48 V (27.1 W)
|
Hardware features
|
- Ports are numbered 0 and 1 from left to right
|
Software features
|
|
Cables and connectors
|
- Duplex LC/PC connector (Rx and Tx)
- Optical interface support—See Table 9
|
LEDs
|
One tricolor Status LED per port:
- Off—Not enabled
- Green—Online with no alarms or failures
- Amber—Online with alarms for remote failures
- Red—Active with a local alarm; router has detected
a failure
|
Alarms, errors, and events
|
SONET alarms:
- Alarm indication signal—line (AIS-L)
- Alarm indication signal—path (AIS-P)
- Bit error rate—signal degrade (BERR-SD)
- Bit error rate—signal fail (BERR-SF)
- Loss of clock (LOC)
- Loss of frame (LOF)
- Loss of light (LOL)
- Loss of pointer (LOP)
- Loss of signal (LOS)
- Payload label mismatch (PLM-P)
- Remote defect indication—line (RDI-L)
- Remote defect indication—path (RDI-P)
- Remote error indication (REI)
- Payload unequipped (unequipped STS at path level) (UNEQ-P)
- Virtual container—alarm indication signal (VAIS)
- Virtual container—loss of clock (VLOC)
- Virtual container—loss of pointer (VLOP)
- Virtual container—mismatch (VMIS)
- Virtual container—remote defect indication (VRD1)
- Virtual container—unequipped (VUNEQ)
|
|
SDH alarms:
- Administrative unit alarm indication signal (AU-AIS)
- Bit error rate signal degrade (BERR-SD)
- Bit error rate signal fail (BERR-SF)
- Bit interleaved parity (BIP) error B1, B2, B3
- Higher order path—alarm indication signal (HP-AIS)
- Higher order path—far-end receiver error (HP-FERF)
- Higher order path—payload label mismatch (HP-PLM)
- Higher order path—loss of pointer (HP-LOP)
- Higher order path—remote defect indication (HP-RDI)
- Higher order path—unequipped (HP-UNEQ)
- Loss of clock (LOC)
- Loss of frame (LOF)
- Loss of light (LOL)
- Loss of signal (LOS)
- Multiplex section—alarm indication signal (MS-AIS)
- Multiplex section—far-end receive error (MS-FERF)
- Multiplex section—remote defect indication (MS-RDI)
- Multiplex section—remote error indication (MS-REI)
- Phase lock loop (PLL)
- Remote error indication (REI)
- Severely errored frame (SEF)
- Tributary unit—alarm indication signal (TU-AIS)
- Tributary unit—loss of clock (TU-LOC)
- Tributary unit—loss of pointer (TU-LOP)
- Tributary unit—mismatch (TU-MIS)
- Tributary unit—remote defect indication (TU-RD1)
- Tributary unit—unequipped (TU-UNEQ)
|
|
-
DS1 alarms:
- Alarm indication signal (AIS)
- Loss of frame (LOF)
- Remote alarm indication signal (RAIS)
-
DS1 error detection:
- Bursty errored seconds (BES)
- CRC errors
- Errored seconds (ES)
- Line errored seconds (LES)
- Loss of framing seconds (LOFS)
- Loss of signal seconds (LOS)
- Severely errored seconds (SES)
- Severely errored framing seconds (SEFS)
- Unavailable seconds (UAS)
-
DS3 alarms:
- Alarm indication signal (AIS)
- Loss of frame (LOF)
- Loss of signal (LOS)
- Phase lock loop (PLL)
-
DS3 error detection:
- C-bit code violations (CCV)
- C-bit errored seconds (CES)
- C-bit severely errored framing seconds (CEFS)
- CRC errors
- Excessive zeros (EXZ)
- Far-end block error (FEBE)
- Far-end receive failure (FERF)
- Line errored seconds (LES)
- Parity bit (P-bit) code violations (PCV)
- Parity bit (P-bit) errored seconds (PES)
- Parity bit (P-bit) severely errored framing seconds (PSES)
- Severely errored framing seconds (SEFS)
- Unavailable seconds (UAS)
|